AI100 48V
النوعانفرترالشبكةتخزينالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVGM
5 kW single-phase hybrid with a 100 A charge limit — the common size for an average home.
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 7.6 |
| Rated power (kW) | 7.6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 14 |
| Rated power (kW) | 14 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 16 |
| Rated power (kW) | 16 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 30 |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| Dimension (mm) | 530 x 228 x 493 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC charge current (A) | 100 |
| Max AC input current (A) | 40 |
| Max AC output power (kW) | 5 |
| Max AC passthrough (A) | 40 |
| Max charge current (A) | 100 |
| Max charge power (kW) | 5 |
| Max discharge current (A) | 100 |
| Max discharge power (kW) | 5 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 25 |
| Max PV input current (A) | 15+15 |
| Max PV input power (kW) | 6.5 |
| Max PV voltage (V) | 550 |
| Max short circuit current (A) | 18+18 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 220-500 |
| MPPT voltage range (V) | 100-500 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 632 x 315 x 570 |
| Package weight (kg) | 39.1 |
| Parallel units | 6 |
| Power factor | 0.99 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| PV voltage working range (V) | 90-550 |
| Rated AC output current (A) | 21.7 |
| Rated PV input voltage (V) | 360 |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 130 |
| Strings per MPPT | 1+1 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 20 |
| Warranty (years) | 10 |
| Weight (kg) | 32.4 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 40 |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 654 x 243 x 430 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC input current (A) | 40 |
| Max AC output power (kW) | 6.6 |
| Max AC passthrough (A) | 40 |
| Max charge current (A) | 135 |
| Max charge power (kW) | 6 |
| Max discharge current (A) | 135 |
| Max discharge power (kW) | 6 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 28.7 |
| Max PV input current (A) | 26+13 |
| Max PV input power (kW) | 9 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+17 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 230-425 |
| MPPT voltage range (V) | 120-425 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Arc Fault Circuit Interrupter (AFCI), Insulation Resistor Detection |
| PV voltage working range (V) | 90-500 |
| Rated AC output current (A) | 26.1 |
| Rated PV input voltage (V) | 380 |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Strings per MPPT | 2+1 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 7.6 |
| Rated power (kW) | 7.6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 40 |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 654 x 243 x 430 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 8.36 |
| Max AC passthrough (A) | 50 |
| Max charge current (A) | 190 |
| Max charge power (kW) | 7.6 |
| Max discharge current (A) | 190 |
| Max discharge power (kW) | 7.6 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 36 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 11.4 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+44 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 230-425 |
| MPPT voltage range (V) | 120-425 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Arc Fault Circuit Interrupter (AFCI), Insulation Resistor Detection |
| PV voltage working range (V) | 90-500 |
| Rated AC output current (A) | 33 |
| Rated PV input voltage (V) | 380 |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 40 |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 654 x 243 x 430 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 8.8 |
| Max AC passthrough (A) | 50 |
| Max charge current (A) | 190 |
| Max charge power (kW) | 8 |
| Max discharge current (A) | 190 |
| Max discharge power (kW) | 8 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 38.3 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 12 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+44 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 230-425 |
| MPPT voltage range (V) | 120-425 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Arc Fault Circuit Interrupter (AFCI), Insulation Resistor Detection |
| PV voltage working range (V) | 90-500 |
| Rated AC output current (A) | 34.8 |
| Rated PV input voltage (V) | 380 |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232, CAN |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 760 x 285 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | IEC 61727, IEC 62116, NRS 097 (in progress) |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 195.5-253 |
| IP rating | IP65 |
| Max AC input current (A) | 60 |
| Max AC passthrough (A) | 100 |
| Max apparent power (kVA) | 13.2 |
| Max charge current (A) | 220 |
| Max discharge current (A) | 220 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 57.4 |
| Max PV access power (kW) | 24 |
| Max PV input current (A) | 26+26+26 |
| Max PV input power (kW) | 19.2 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+44+44 |
| Monitor module | WiFi/Bluetooth |
| MPPT count | 3 |
| MPPT voltage range (V) | 150-425 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 895 x 419 x 570 |
| Package weight (kg) | 63.6 |
| Parallel units | 6 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
| Rated AC output current (A) | 52.2 |
| Rated PV input voltage (V) | 370 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 53 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 14 |
| Rated power (kW) | 14 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232, CAN |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 760 x 285 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | IEC 61727, IEC 62116, NRS 097 (in progress) |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 195.5-253 |
| IP rating | IP65 |
| Max AC input current (A) | 70 |
| Max AC passthrough (A) | 100 |
| Max apparent power (kVA) | 15.4 |
| Max charge current (A) | 250 |
| Max discharge current (A) | 250 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 67 |
| Max PV access power (kW) | 28 |
| Max PV input current (A) | 26+26+26 |
| Max PV input power (kW) | 22.4 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+44+44 |
| Monitor module | WiFi/Bluetooth |
| MPPT count | 3 |
| MPPT voltage range (V) | 150-425 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 895 x 419 x 570 |
| Package weight (kg) | 63.6 |
| Parallel units | 6 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
| Rated AC output current (A) | 60.9 |
| Rated PV input voltage (V) | 370 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 53 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 16 |
| Rated power (kW) | 16 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232, CAN |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 760 x 285 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | IEC 61727, IEC 62116, NRS 097 (in progress) |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 195.5-253 |
| IP rating | IP65 |
| Max AC input current (A) | 80 |
| Max AC passthrough (A) | 100 |
| Max apparent power (kVA) | 17.6 |
| Max charge current (A) | 290 |
| Max discharge current (A) | 290 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 76.5 |
| Max PV access power (kW) | 32 |
| Max PV input current (A) | 26+26+26 |
| Max PV input power (kW) | 25.6 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+44+44 |
| Monitor module | WiFi/Bluetooth |
| MPPT count | 3 |
| MPPT voltage range (V) | 150-425 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 895 x 419 x 570 |
| Package weight (kg) | 63.6 |
| Parallel units | 6 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
| Rated AC output current (A) | 69.6 |
| Rated PV input voltage (V) | 370 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 53 |
AI100 48V
النوعانفرترالشبكةتخزينالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVAM 48V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVBM 48V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVCM 12V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة2 kW
السعر—
التفاصيل
IVCM 24V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة3.2 kW
السعر—
التفاصيل
IVDM 24V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة4.2 kW
السعر—
التفاصيل