AI100 48V
النوعانفرترالشبكةتخزينالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVGM
18 kW three-phase hybrid with a 330 A charge limit, for a guest house or a small business.
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 14 |
| Rated power (kW) | 14 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 15 |
| Rated power (kW) | 15 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 16 |
| Rated power (kW) | 16 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 18 |
| Rated power (kW) | 18 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 20 |
| Rated power (kW) | 20 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 750 x 268 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC input current (A) | 16 |
| Max AC passthrough (A) | 70 |
| Max altitude (m) | 2000 |
| Max apparent power (kVA) | 11 |
| Max charge current (A) | 210 |
| Max discharge current (A) | 210 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 16 |
| Max output overcurrent protection (A) | 65 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 15 |
| Max PV voltage (V) | 800 |
| Max short circuit current (A) | 39+39 |
| Monitor module | WiFi/4G |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 289-800 |
| MPPT voltage range (V) | 160-650 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 889 x 397 x 566 |
| Package weight (kg) | 60.2 |
| Parallel units | 10 |
| Pass through without battery | Yes |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated AC output current (A) | 14.5 |
| Rated PV input voltage (V) | 550 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 5/10 (depends on installation site) |
| Weight (kg) | 48.7 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 750 x 268 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC input current (A) | 19.2 |
| Max AC passthrough (A) | 45 |
| Max apparent power (kVA) | 13.2 |
| Max charge current (A) | 240 |
| Max discharge current (A) | 240 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 19.2 |
| Max output overcurrent protection (A) | 65 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 18 |
| Max PV voltage (V) | 800 |
| Max short circuit current (A) | 39+39 |
| Monitor module | WiFi/4G |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 347-800 |
| MPPT voltage range (V) | 160-650 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 889 x 397 x 566 |
| Package weight (kg) | 60.2 |
| Parallel units | 10 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated AC output current (A) | 17.4 |
| Rated PV input voltage (V) | 550 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 5/10 (depends on installation site) |
| Weight (kg) | 48.7 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 14 |
| Rated power (kW) | 14 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 750 x 268 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC input current (A) | 22.3 |
| Max AC passthrough (A) | 70 |
| Max apparent power (kVA) | 15.4 |
| Max charge current (A) | 260 |
| Max discharge current (A) | 260 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 22.3 |
| Max output overcurrent protection (A) | 92 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 22.4 |
| Max PV voltage (V) | 800 |
| Max short circuit current (A) | 39+39 |
| Monitor module | WiFi/4G |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 389-800 |
| MPPT voltage range (V) | 160-650 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 889 x 397 x 566 |
| Package weight (kg) | 60.2 |
| Parallel units | 10 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated AC output current (A) | 20.3 |
| Rated PV input voltage (V) | 550 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 5/10 (depends on installation site) |
| Weight (kg) | 48.7 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 15 |
| Rated power (kW) | 15 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 750 x 268 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC input current (A) | 23.9 |
| Max AC passthrough (A) | 70 |
| Max apparent power (kVA) | 16.5 |
| Max charge current (A) | 280 |
| Max discharge current (A) | 280 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 23.9 |
| Max output overcurrent protection (A) | 92 |
| Max PV input current (A) | 36+36 |
| Max PV input power (kW) | 24 |
| Max PV voltage (V) | 800 |
| Max short circuit current (A) | 54+54 |
| Monitor module | WiFi/4G |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 416-800 |
| MPPT voltage range (V) | 160-650 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 889 x 397 x 566 |
| Package weight (kg) | 60.2 |
| Parallel units | 10 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated AC output current (A) | 21.8 |
| Rated PV input voltage (V) | 550 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 5/10 (depends on installation site) |
| Weight (kg) | 48.7 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 16 |
| Rated power (kW) | 16 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 750 x 268 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC input current (A) | 25.5 |
| Max AC passthrough (A) | 70 |
| Max apparent power (kVA) | 17.6 |
| Max charge current (A) | 300 |
| Max discharge current (A) | 300 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 25.5 |
| Max output overcurrent protection (A) | 92 |
| Max PV input current (A) | 36+36 |
| Max PV input power (kW) | 25.6 |
| Max PV voltage (V) | 800 |
| Max short circuit current (A) | 54+54 |
| Monitor module | WiFi/4G |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 445-800 |
| MPPT voltage range (V) | 160-650 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 889 x 397 x 566 |
| Package weight (kg) | 60.2 |
| Parallel units | 10 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated AC output current (A) | 23.2 |
| Rated PV input voltage (V) | 550 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 5/10 (depends on installation site) |
| Weight (kg) | 48.7 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 18 |
| Rated power (kW) | 18 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 750 x 268 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC input current (A) | 28.7 |
| Max AC passthrough (A) | 70 |
| Max apparent power (kVA) | 19.8 |
| Max charge current (A) | 330 |
| Max discharge current (A) | 330 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 28.7 |
| Max output overcurrent protection (A) | 92 |
| Max PV input current (A) | 36+36 |
| Max PV input power (kW) | 28.8 |
| Max PV voltage (V) | 800 |
| Max short circuit current (A) | 54+54 |
| Monitor module | WiFi/4G |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 500-800 |
| MPPT voltage range (V) | 160-650 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 889 x 397 x 566 |
| Package weight (kg) | 60.2 |
| Parallel units | 10 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated AC output current (A) | 26.1 |
| Rated PV input voltage (V) | 550 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 5/10 (depends on installation site) |
| Weight (kg) | 48.7 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 20 |
| Rated power (kW) | 20 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 750 x 268 x 450 |
| Display | LCD |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC input current (A) | 31.9 |
| Max AC passthrough (A) | 70 |
| Max apparent power (kVA) | 22 |
| Max charge current (A) | 350 |
| Max discharge current (A) | 350 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 31.9 |
| Max output overcurrent protection (A) | 92 |
| Max PV input current (A) | 36+36 |
| Max PV input power (kW) | 32 |
| Max PV voltage (V) | 800 |
| Max short circuit current (A) | 54+54 |
| Monitor module | WiFi/4G |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 550-800 |
| MPPT voltage range (V) | 160-650 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 889 x 397 x 566 |
| Package weight (kg) | 60.2 |
| Parallel units | 10 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection |
| Rated AC output current (A) | 28.9 |
| Rated PV input voltage (V) | 550 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 5/10 (depends on installation site) |
| Weight (kg) | 48.7 |
AI100 48V
النوعانفرترالشبكةتخزينالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVAM 48V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVBM 48V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVCM 12V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة2 kW
السعر—
التفاصيل
IVCM 24V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة3.2 kW
السعر—
التفاصيل
IVDM 24V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة4.2 kW
السعر—
التفاصيل