- Home
- Products
- Felicity
- Inverter
- Hybrid








Felicity T-REX Hybrid inverter 29.9 kW
TypeInverterGridHybridPhaseThree phaseBatteryHigh voltage
Capacity10 kW25 kW29.9 kW30 kW40 kW50 kW
29.9 kW three-phase hybrid with three trackers, sized to sit just under a 30 kW connection limit.
| AC output voltage (V) | 220/230 |
|---|
| Battery type | LiFePO4 |
|---|
| IP rating | IP65 |
|---|
| Max charge current (A) | 50+50 |
|---|
| Max efficiency (%) | 97.6 |
|---|
| Max PV input power (kW) | 38.87 |
|---|
| Max PV voltage (V) | 1000 |
|---|
| MPPT count | 3 |
|---|
All specifications72
AC
| AC output voltage (V) | 220/230 |
|---|
| Grid type | Hybrid |
|---|
| Phase | Three phase |
|---|
| AC grid connection type | 3L+N+PE |
|---|
| AC input voltage (V) | 220-230 |
|---|
| AC output line voltage (V) | 380-400 |
|---|
| Grid frequency (Hz) | 50/60 |
|---|
| Grid frequency range 50 (Hz) | 45-55 |
|---|
| Grid frequency range 60 (Hz) | 55-65 |
|---|
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, NC RFG (Poland), VDE 4105, G99, EN 50549-1, EN 50549-1+Netherlands |
|---|
| Max AC output power (kW) | 29.9 |
|---|
| Max AC passthrough (A) | 200 |
|---|
| Max output current (A) | 43.4 |
|---|
| Nominal AC input line voltage (V) | 380-400 |
|---|
| Output frequency (Hz) | 50/60 |
|---|
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
|---|
| Rated AC output current (A) | 43.4 |
|---|
| THD (%) | 3 |
|---|
PV and DC
| Max PV input current (A) | 36+36+36 |
|---|
| Max PV input power (kW) | 38.87 |
|---|
| Max PV voltage (V) | 1000 |
|---|
| Min DC input voltage (V) | 150 |
|---|
| Monitor module | WiFi/GPRS |
|---|
| MPPT count | 3 |
|---|
| MPPT efficiency (%) | 99.9 |
|---|
| MPPT full load voltage range (V) | 360-850 |
|---|
| MPPT voltage range (V) | 200-850 |
|---|
| Overvoltage category DC | II |
|---|
| Rated PV input voltage (V) | 600 |
|---|
| Strings per MPPT | 2 |
|---|
| Surge protection level DC | II |
|---|
Battery
| Battery class | High voltage |
|---|
| Battery type | LiFePO4 |
|---|
| Battery voltage range (V) | 160-800 |
|---|
| BMS communication | RS485, CAN |
|---|
| Charge algorithm | Self-adaption to BMS |
|---|
| Max charge current (A) | 50+50 |
|---|
| Max discharge current (A) | 50+50 |
|---|
| Number of battery inputs | 2 |
|---|
| Approved battery families | Felicity |
|---|
Protection
| AC short circuit protection | Yes |
|---|
| Ground fault monitoring | Yes |
|---|
| IP rating | IP65 |
|---|
| Max output overcurrent protection (A) | 144 |
|---|
| Max short circuit current (A) | 55+55+55 |
|---|
| Overload protection | Yes |
|---|
| Overvoltage category AC | III |
|---|
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
|---|
| Surge duration (s) | 10 |
|---|
| Surge power multiple | 1.5 |
|---|
| Surge protection level AC | II |
|---|
Communication
| Communication interface | RS485, RS232 |
|---|
| Display | LCD |
|---|
General
| Rated power (kVA) | 29.9 |
|---|
| Rated power (kW) | 29.9 |
|---|
| Cooling | Air Cooling |
|---|
| Dimension (mm) | 940 x 340 x 582 |
|---|
| European efficiency (%) | 97 |
|---|
| Input voltage range (V) | 184-264.5 |
|---|
| Max altitude (m) | 3000 (>2000 derating) |
|---|
| Max efficiency (%) | 97.6 |
|---|
| Operating temperature (°C) | -25 to 60 (>50 derating) |
|---|
| Package dimension (mm) | 1114 x 469 x 774 |
|---|
| Package weight (kg) | 102.3 |
|---|
| Parallel units | 12 |
|---|
| Relative humidity (%) | 0-95 (non-condensing) |
|---|
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
|---|
| Startup voltage (V) | 250 |
|---|
| Topology | Non-Isolated |
|---|
| Transfer time (ms) | 10 |
|---|
| Warranty (years) | 10 |
|---|
| Weight (kg) | 85.6 |
|---|


IVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltage

IVEM 48V IITypeInverterGridOff-gridPhaseSingle phaseCapacity6 kW8 kW12 kWBatteryLow voltage

ICONTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVABatteryLow voltage

OPTIMUSTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVA1.6 kVABatteryLow voltage

AXPERT KING II TWIN 5G HELIUSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltage

AXPERT KING II TWIN AGSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltage