TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité0.6 kVA
Prix—
Détails
INFINISOLAR WP TWIN HMI
15 kW across two controllable outputs with a 300 A charger, the larger of the twin-output pair.
| AC output voltage (V) | 230 (P-N) / 400 (P-P) |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 12 |
| Communication interface | RS232/RS485/USB/CAN/WIFI |
| Dimension (mm) | 660 x 255 x 750 |
| European efficiency (%) | 95 |
| AC output voltage (V) | 230 (P-N) / 400 (P-P) |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 15 |
| Communication interface | RS232/RS485/USB/CAN/WIFI |
| Dimension (mm) | 660 x 255 x 750 |
| European efficiency (%) | 95 |
| AC output voltage (V) | 230 (P-N) / 400 (P-P) |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 12 |
| Battery mode efficiency (%) | 91 |
| Communication interface | RS232/RS485/USB/CAN/WIFI |
| Dimension (mm) | 660 x 255 x 750 |
| European efficiency (%) | 95 |
| Input voltage range (V) | 170-290 |
| Max altitude (m) | 1000 |
| Max charge current (A) | 250 |
| Max charge power (kW) | 12 |
| Max efficiency (%) | 96 |
| Max PV input current (A) | 26 |
| Max PV input power (kW) | 16 |
| Max PV voltage (V) | 1000 |
| MPPT voltage range (V) | 350-950 |
| Operating temperature (°C) | -25 to 60 |
| Parallel units | 6 |
| Power factor adjustable range | 0.9 leading to 0.9 lagging |
| Rated AC output current (A) | 17.4 |
| Relative humidity (%) | 0-100 |
| Safety standard | IEC 62109, IEC 62116, IEC 61727, IEC 61683 |
| Waveform | Pure sine wave |
| Weight (kg) | 75 |
| AC output voltage (V) | 230 (P-N) / 400 (P-P) |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 15 |
| Battery mode efficiency (%) | 91 |
| Communication interface | RS232/RS485/USB/CAN/WIFI |
| Dimension (mm) | 660 x 255 x 750 |
| European efficiency (%) | 95 |
| Input voltage range (V) | 170-290 |
| Max altitude (m) | 1000 |
| Max charge current (A) | 300 |
| Max charge power (kW) | 15 |
| Max efficiency (%) | 96 |
| Max PV input current (A) | 26 |
| Max PV input power (kW) | 22.5 |
| Max PV voltage (V) | 1000 |
| MPPT voltage range (V) | 350-950 |
| Operating temperature (°C) | -25 to 60 |
| Parallel units | 6 |
| Power factor adjustable range | 0.9 leading to 0.9 lagging |
| Rated AC output current (A) | 21.7 |
| Relative humidity (%) | 0-100 |
| Safety standard | IEC 62109, IEC 62116, IEC 61727, IEC 61683 |
| Waveform | Pure sine wave |
| Weight (kg) | 78 |
ATOM
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité0.6 kVA
Prix—
Détails
ATOM LOBO
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT IND
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING