ATOM
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité0.6 kVA
Prix—
Détails
AXPERT IND
1.2 kW for a single room, a kiosk or a lighting-and-electronics backup.
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 330 x 104 x 414 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 3.2 |
| Rated power (kW) | 3.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 5.2 |
| Rated power (kW) | 5.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 6.5 |
| Rated power (kW) | 6.5 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 12 |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 330 x 104 x 414 |
| Floating charge voltage (V) | 13.5 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 70 |
| Max charge current (A) | 90 |
| Max efficiency (%) | 90 |
| Max PV input current (A) | 13 |
| Max PV input power (kW) | 2 |
| Max PV voltage (V) | 350 |
| Max solar charge current (A) | 90 |
| MPPT voltage range (V) | 30-300 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 16 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 2.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 9 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 90 |
| Max charge current (A) | 110 |
| Max efficiency (%) | 90 |
| Max PV input current (A) | 13 |
| Max PV input power (kW) | 3 |
| Max PV voltage (V) | 450 |
| Max solar charge current (A) | 110 |
| MPPT voltage range (V) | 30-400 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 31 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 5 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 8.7 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 3.2 |
| Rated power (kW) | 3.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 90 |
| Max charge current (A) | 110 |
| Max efficiency (%) | 90 |
| Max PV input current (A) | 18 |
| Max PV input power (kW) | 4 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 110 |
| MPPT voltage range (V) | 30-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 31 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 6.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 11.6 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 5.2 |
| Rated power (kW) | 5.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 90 |
| Max charge current (A) | 90 |
| Max efficiency (%) | 91 |
| Max PV input current (A) | 18 |
| Max PV input power (kW) | 5.5 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 90 |
| MPPT voltage range (V) | 90-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 63 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 10.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 13 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 6.5 |
| Rated power (kW) | 6.5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 100 |
| Max charge current (A) | 120 |
| Max efficiency (%) | 91 |
| Max PV input current (A) | 22 |
| Max PV input power (kW) | 8 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 120 |
| MPPT voltage range (V) | 90-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 66 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 13 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 14.5 |
ATOM
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité0.6 kVA
Prix—
Détails
ATOM LOBO
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING II
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING II TWIN
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING II TWIN 5G HELIUS
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité6.2 kW
Prix$478
Détails