TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité0.6 kVA
Prix—
Détails
AXPERT VM II PREMIUM
1.2 kW on a 12 V bank with a 100 A charger, the fastest-charging small machine in the VM II family.
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 3 |
| Rated power (kW) | 3 |
| AC input voltage (V) | 230 |
| Dimension (mm) | 300 x 100 x 440 |
| Grid frequency (Hz) | 50/60 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC input voltage (V) | 230 |
| Dimension (mm) | 300 x 100 x 440 |
| Grid frequency (Hz) | 50/60 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 12 |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Floating charge voltage (V) | 13.5 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 80 |
| Max charge current (A) | 80 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 2 |
| Max PV voltage (V) | 350 |
| Max solar charge current (A) | 80 |
| MPPT voltage range (V) | 60-300 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 16 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 2.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 6.5 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Max AC charge current (A) | 80 |
| Max AC input voltage (V) | 300 |
| Max charge current (A) | 80 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 3 |
| Max PV voltage (V) | 450 |
| Max solar charge current (A) | 80 |
| MPPT voltage range (V) | 60-400 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 32 |
| PV voltage accuracy (V) | 2 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Startup voltage (V) | 23 |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 5 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 7.1 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 3 |
| Rated power (kW) | 3 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | USB/RS232 (optional USB/Dry-contact) |
| Dimension (mm) | 300 x 100 x 440 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Max AC charge current (A) | 100 |
| Max AC input voltage (V) | 300 |
| Max charge current (A) | 100 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 4 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 100 |
| MPPT voltage range (V) | 120-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 33 |
| PV voltage accuracy (V) | 2 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Startup voltage (V) | 23 |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 6 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 9 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | USB/RS232 (optional USB/Dry-contact) |
| Dimension (mm) | 300 x 100 x 440 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Max AC charge current (A) | 100 |
| Max AC input voltage (V) | 300 |
| Max charge current (A) | 100 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 5 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 100 |
| MPPT voltage range (V) | 120-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 63 |
| PV voltage accuracy (V) | 2 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Startup voltage (V) | 23 |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 10 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 10 |
ATOM
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité0.6 kVA
Prix—
Détails
ATOM LOBO
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT IND
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING II
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
AXPERT KING II TWIN
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—