AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVPM 48V
7.5 kVA off-grid, 6,000 W continuous, with a 60 A charge limit, for a larger home or a shop.
| AC output voltage (V) | 220 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 4 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220 |
| AC output voltage (V) | 220 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 7.5 |
| Rated power (kW) | 6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220 |
| AC output voltage (V) | 220 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220 |
| AC output voltage (V) | 220 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 4 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220 |
| AC short circuit protection | Yes |
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
| Battery voltage range (V) | 42-63 |
| BMS communication | RS485 |
| Bulk charging voltage (V) | 57.6 |
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Communication interface | RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 494 x 195 x 420 |
| Display | LCD, LED |
| Floating charge voltage (V) | 54.4 |
| Grid frequency (Hz) | 50/60 |
| High DC input recovery (V) | 62 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Input voltage range (V) | 90-280 |
| Input voltage waveform | Sinusoidal (utility or generator) |
| IP rating | IP21 |
| Line mode efficiency (%) | 95 |
| Line mode output waveform | Same As Input Waveform |
| Low battery recovery load over 50pct (V) | 46 |
| Low battery recovery load under 50pct (V) | 47 |
| Low DC input shutdown load over 50pct (V) | 42 |
| Low DC input shutdown load under 50pct (V) | 43 |
| Low line disconnect apl (V) | 90 |
| Low line disconnect UPS (V) | 170 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Low line reconnect UPS (V) | 180 |
| Max AC charge current (A) | 50 |
| Max AC input voltage (V) | 280 |
| Max AC passthrough (A) | 63 |
| Max charge current (A) | 50 |
| Max charging voltage (V) | 61.0 |
| Max efficiency (%) | 90 |
| Max PV input power (kW) | 6.6 |
| Max PV voltage (V) | 170 |
| Max solar charge current (A) | 120 |
| Motor start capable | Yes |
| MPPT count | 1 |
| MPPT voltage range (V) | 65-145 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | 0-40 |
| Output frequency (Hz) | 50/60 |
| Output voltage regulation (%) | 5 |
| Overload protection | Air Switch Protection |
| Overload trip time over 105pct load (s) | 10 |
| Overload trip time over 150pct load (s) | 5 |
| Package dimension (mm) | 607 x 290 x 540 |
| Package weight (kg) | 39.7 |
| Parallel units | 6 |
| Pass through without battery | No |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| PV voltage working range (V) | 65-145 |
| Short circuit protection line mode | Air Switch Protection |
| Startup voltage (V) | 46 |
| Storage temperature (°C) | -15 to 60 |
| Strings per MPPT | 1 |
| Surge duration (s) | 5 |
| Surge power multiple | 2 |
| Topology | Low-Frequency (transformer-based) |
| Transfer time (ms) | 15 |
| Waveform | Pure sine wave |
| Weight (kg) | 36.3 |
| AC output voltage (V) | 220 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 7.5 |
| Rated power (kW) | 6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220 |
| AC short circuit protection | Yes |
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
| Battery voltage range (V) | 42-63 |
| BMS communication | RS485 |
| Bulk charging voltage (V) | 57.6 |
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Communication interface | RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 494 x 195 x 420 |
| Display | LCD, LED |
| Floating charge voltage (V) | 54.4 |
| Grid frequency (Hz) | 50/60 |
| High DC input recovery (V) | 62 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Input voltage range (V) | 90-280 |
| Input voltage waveform | Sinusoidal (utility or generator) |
| IP rating | IP21 |
| Line mode efficiency (%) | 95 |
| Line mode output waveform | Same As Input Waveform |
| Low battery recovery load over 50pct (V) | 46 |
| Low battery recovery load under 50pct (V) | 47 |
| Low DC input shutdown load over 50pct (V) | 42 |
| Low DC input shutdown load under 50pct (V) | 43 |
| Low line disconnect apl (V) | 90 |
| Low line disconnect UPS (V) | 170 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Low line reconnect UPS (V) | 180 |
| Max AC charge current (A) | 60 |
| Max AC input voltage (V) | 280 |
| Max AC passthrough (A) | 63 |
| Max charge current (A) | 60 |
| Max charging voltage (V) | 61.0 |
| Max efficiency (%) | 90 |
| Max PV input power (kW) | 6.6 |
| Max PV voltage (V) | 170 |
| Max solar charge current (A) | 120 |
| Motor start capable | Yes |
| MPPT count | 1 |
| MPPT voltage range (V) | 65-145 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | 0-40 |
| Output frequency (Hz) | 50/60 |
| Output voltage regulation (%) | 5 |
| Overload protection | Air Switch Protection |
| Overload trip time over 105pct load (s) | 10 |
| Overload trip time over 150pct load (s) | 5 |
| Package dimension (mm) | 607 x 290 x 540 |
| Package weight (kg) | 39.7 |
| Parallel units | 6 |
| Pass through without battery | No |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| PV voltage working range (V) | 65-145 |
| Short circuit protection line mode | Air Switch Protection |
| Startup voltage (V) | 46 |
| Storage temperature (°C) | -15 to 60 |
| Strings per MPPT | 1 |
| Surge duration (s) | 5 |
| Surge power multiple | 2 |
| Topology | Low-Frequency (transformer-based) |
| Transfer time (ms) | 15 |
| Waveform | Pure sine wave |
| Weight (kg) | 36.3 |
| AC output voltage (V) | 220 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 220 |
| AC short circuit protection | Yes |
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
| Battery voltage range (V) | 42-63 |
| BMS communication | RS485 |
| Bulk charging voltage (V) | 57.6 |
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Communication interface | RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 584 x 195 x 420 |
| Display | LCD, LED |
| Floating charge voltage (V) | 54.4 |
| Grid frequency (Hz) | 50/60 |
| High DC input recovery (V) | 62 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Input voltage range (V) | 90-280 |
| Input voltage waveform | Sinusoidal (utility or generator) |
| IP rating | IP21 |
| Line mode efficiency (%) | 95 |
| Line mode output waveform | Same As Input Waveform |
| Low battery recovery load over 50pct (V) | 46 |
| Low battery recovery load under 50pct (V) | 47 |
| Low DC input shutdown load over 50pct (V) | 42 |
| Low DC input shutdown load under 50pct (V) | 43 |
| Low line disconnect apl (V) | 90 |
| Low line disconnect UPS (V) | 170 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Low line reconnect UPS (V) | 180 |
| Max AC charge current (A) | 80 |
| Max AC input voltage (V) | 280 |
| Max AC passthrough (A) | 63 |
| Max charge current (A) | 80 |
| Max charging voltage (V) | 61.0 |
| Max efficiency (%) | 90 |
| Max PV input power (kW) | 6.6 |
| Max PV voltage (V) | 170 |
| Max solar charge current (A) | 120 |
| Motor start capable | Yes |
| MPPT count | 1 |
| MPPT voltage range (V) | 65-145 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | 0-40 |
| Output frequency (Hz) | 50/60 |
| Output voltage regulation (%) | 5 |
| Overload protection | Air Switch Protection |
| Overload trip time over 105pct load (s) | 10 |
| Overload trip time over 150pct load (s) | 5 |
| Package dimension (mm) | 670 x 355 x 470 |
| Package weight (kg) | 67.7 |
| Parallel units | 6 |
| Pass through without battery | No |
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
| PV voltage working range (V) | 65-145 |
| Short circuit protection line mode | Air Switch Protection |
| Startup voltage (V) | 46 |
| Storage temperature (°C) | -15 to 60 |
| Strings per MPPT | 1 |
| Surge duration (s) | 5 |
| Surge power multiple | 2 |
| Topology | Low-Frequency (transformer-based) |
| Transfer time (ms) | 15 |
| Waveform | Pure sine wave |
| Weight (kg) | 55.4 |
AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVAM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVBM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVCM 12V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité2 kW
Prix—
Détails
IVCM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité3.2 kW
Prix—
Détails
IVDM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité4.2 kW
Prix—
Détails