- Home
- Products
- Deye
- Inverter
- Hybrid
A 12 kW three-phase hybrid on a 48 V battery, charging at up to 240 A.
| AC output voltage (V) | 220/380, 230/400 |
|---|
| Battery type | Lead-acid, Lithium-ion |
|---|
| IP rating | IP65 |
|---|
| Max charge current (A) | 240 |
|---|
| Max efficiency (%) | 97.6 |
|---|
| Max PV input power (kW) | 19.2 |
|---|
| Max PV voltage (V) | 800 |
|---|
| MPPT count | 2 |
|---|
All specifications82
AC
| AC output voltage (V) | 220/380, 230/400 |
|---|
| Grid type | Hybrid |
|---|
| Phase | Three phase |
|---|
| AC couple support | Yes |
|---|
| AC grid connection type | 3L+N+PE |
|---|
| AC voltage tolerance un | 0.85-1.1 |
|---|
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
|---|
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
|---|
| Max AC passthrough (A) | 45 |
|---|
| Max apparent power (kVA) | 13.2 |
|---|
| Max output current (A) | 20/19.2 |
|---|
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
|---|
| Rated AC output current (A) | 18.2/17.4 |
|---|
| THD (%) | 3 |
|---|
| Unbalanced output (%) | 100 |
|---|
| Unbalanced output per phase (%) | 50 |
|---|
PV and DC
| DC component monitoring | Yes |
|---|
| DC injection current pct of in | 0.5 |
|---|
| DC reverse polarity protection | Yes |
|---|
| DC switch | Yes |
|---|
| Max PV access power (kW) | 24 |
|---|
| Max PV input current (A) | 26+26 |
|---|
| Max PV input power (kW) | 19.2 |
|---|
| Max PV voltage (V) | 800 |
|---|
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
|---|
| MPPT count | 2 |
|---|
| MPPT efficiency (%) | 99 |
|---|
| MPPT voltage range (V) | 200-650 |
|---|
| Overvoltage category DC | II |
|---|
| Rated PV input voltage (V) | 550 |
|---|
| Strings per MPPT | 2+2 |
|---|
| Surge protection level DC | II |
|---|
Battery
| Battery class | Low voltage |
|---|
| Nominal battery voltage (V) | 48 |
|---|
| Battery parallel support | Yes |
|---|
| Battery type | Lead-acid, Lithium-ion |
|---|
| Battery voltage range (V) | 40-60 |
|---|
| Charge algorithm | Self-adaption to BMS |
|---|
| Charge discharge time periods | 6 |
|---|
| Max charge current (A) | 240 |
|---|
| Max discharge current (A) | 240 |
|---|
| Number of battery inputs | 1 |
|---|
| Approved battery families | Deye, Dyness, Pylontech, BYD, LG, FinDreams, Weco, Alpha ESS, Hubble, Freedom Won, Shoto, Sunwoda, Jinko, Narada, Vision, Wattsonic, Sacred Sun, GenixGreen, ACE |
|---|
Protection
| AC output overcurrent protection | Yes |
|---|
| AC output overvoltage protection | Yes |
|---|
| AC short circuit protection | Yes |
|---|
| AFCI protection | Optional |
|---|
| Anti islanding protection | Yes |
|---|
| Insulation resistance monitoring | Yes |
|---|
| IP rating | IP65 |
|---|
| Max short circuit current (A) | 39+39 |
|---|
| Overload protection | Yes |
|---|
| Overvoltage category AC | III |
|---|
| Surge duration (s) | 10 |
|---|
| Surge power multiple | 2 |
|---|
| Surge protection level AC | II |
|---|
| Thermal protection | Yes |
|---|
Communication
| Communication interface | RS485, CAN, WIFI |
|---|
| Display | LCD |
|---|
| Grid monitoring | Yes |
|---|
| Residual current monitoring | Yes |
|---|
General
| Rated power (kW) | 12 |
|---|
| Cooling | Air Cooling |
|---|
| Derating start temp (°C) | 45 |
|---|
| Dimension (mm) | 386 x 250 x 660 |
|---|
| European efficiency (%) | 97.0 |
|---|
| Generator support | Yes (Diesel) |
|---|
| Max altitude (m) | 3000 |
|---|
| Max efficiency (%) | 97.6 |
|---|
| Max inverter backfeed current (A) | 0 |
|---|
| Noise (dB) | 55 |
|---|
| Operating temperature (°C) | -40 to 60 |
|---|
| Package weight (kg) | 61 |
|---|
| Package volume m3 | 0.18667 |
|---|
| Hs code | 85044090 |
|---|
| Parallel units | 10 |
|---|
| Relative humidity (%) | 0-100 |
|---|
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
|---|
| Startup voltage (V) | 160 |
|---|
| Topology | Non-Isolated |
|---|
| Warranty (years) | 5/10 |
|---|
| Weight (kg) | 35.2 |
|---|