- Home
- Products
- Deye
- Inverter
- On-grid
A 45 kW three-phase on-grid inverter with three trackers, for a commercial or industrial array.
| AC output voltage (V) | 220/380, 230/400 |
|---|
| IP rating | IP65 |
|---|
| Max efficiency (%) | 98.7 |
|---|
| Max PV input power (kW) | 58.5 |
|---|
| Max PV voltage (V) | 1100 |
|---|
| MPPT count | 3 |
|---|
| MPPT voltage range (V) | 200-1000 |
|---|
| Warranty (years) | 5 |
|---|
All specifications63
AC
| AC output voltage (V) | 220/380, 230/400 |
|---|
| Grid type | On-grid |
|---|
| Phase | Three phase |
|---|
| AC grid connection type | 3L+N+PE |
|---|
| AC voltage tolerance un | 0.85-1.1 |
|---|
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
|---|
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549-1, NRS 097, G98, G99, VDE-AR-N 4105, NC RFG |
|---|
| Max apparent power (kVA) | 49.5 |
|---|
| Max output current (A) | 75/71.7 |
|---|
| Max output fault current (A) | 130.4 |
|---|
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
|---|
| Rated AC output current (A) | 68.2/65.2 |
|---|
| THD (%) | 3 |
|---|
PV and DC
| DC component monitoring | Yes |
|---|
| DC injection current pct of in | 0.5 |
|---|
| DC reverse polarity protection | Yes |
|---|
| DC switch | Yes |
|---|
| Max PV input current (A) | 40+40+40 |
|---|
| Max PV input power (kW) | 58.5 |
|---|
| Max PV voltage (V) | 1100 |
|---|
| MPPT count | 3 |
|---|
| MPPT efficiency (%) | 99 |
|---|
| MPPT full load voltage range (V) | 450-850 |
|---|
| MPPT voltage range (V) | 200-1000 |
|---|
| Overvoltage category DC | II |
|---|
| Rated PV input voltage (V) | 600 |
|---|
| String monitoring | Optional |
|---|
| Strings per MPPT | 3+3+3 |
|---|
| Surge protection level DC | II |
|---|
Protection
| AC output overcurrent protection | Yes |
|---|
| AC output overvoltage protection | Yes |
|---|
| AC short circuit protection | Yes |
|---|
| AFCI protection | Optional |
|---|
| Anti islanding protection | Yes |
|---|
| Insulation resistance monitoring | Yes |
|---|
| IP rating | IP65 |
|---|
| Max output overcurrent protection (A) | 132.5 |
|---|
| Max short circuit current (A) | 60+60+60 |
|---|
| Overvoltage category AC | III |
|---|
| Surge protection level AC | II |
|---|
| Thermal protection | Yes |
|---|
Communication
| Communication interface | RS485, RS232, WIFI, LAN |
|---|
| Display | LCD |
|---|
| Residual current monitoring | Yes |
|---|
General
| Rated power (kW) | 45 |
|---|
| Anti PID | Optional |
|---|
| Cooling | Air Cooling |
|---|
| Derating start temp (°C) | 45 |
|---|
| Dimension (mm) | 434 x 243 x 570 |
|---|
| European efficiency (%) | 98.1 |
|---|
| Max altitude (m) | 4000 |
|---|
| Max efficiency (%) | 98.7 |
|---|
| Max inverter backfeed current (A) | 0 |
|---|
| Noise (dB) | 65 |
|---|
| Operating temperature (°C) | -25 to 60 |
|---|
| Relative humidity (%) | 0-100 |
|---|
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
|---|
| Startup voltage (V) | 250 |
|---|
| Topology | Non-Isolated |
|---|
| Vsg support | Yes |
|---|
| Warranty (years) | 5 |
|---|
| Weight (kg) | 39 |
|---|
| Zero export support | Yes |
|---|