TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltageSystem48 V Capacity6 kW8 kW12 kW
Price3,386 SAR

In stock · Delivery in 5 business days

Description

12 kW off-grid with a 240 A charge limit — the largest single-phase machine in the line, for heavy loads on one inverter.

Key specifications

AC output voltage (V)230
IP ratingIP21
Max charge current (A)240
Max efficiency (%)93
Max PV input power (kW)15
Max PV voltage (V)500
MPPT count1
MPPT voltage range (V)90-450
All specifications74

AC

AC output voltage (V)230
Grid typeOff-grid
PhaseSingle phase
AC grid connection typeL+N+PE
AC input voltage (V)230
Grid frequency (Hz)50/60
High line frequency reconnect (Hz)63
Max AC input voltage (V)280
Max AC passthrough (A)63
Output frequency (Hz)50/60
Output voltage regulation (%)5

PV and DC

High line disconnect (V)280
High line frequency disconnect (Hz)65
Low line disconnect apl (V)90
Low line disconnect UPS (V)170
Low line frequency disconnect (Hz)40
Max PV input current (A)27+27
Max PV input power (kW)15
Max PV voltage (V)500
Monitor moduleBuilt-In WiFi
MPPT count1
MPPT voltage range (V)90-450
PV voltage working range (V)90-450
Strings per MPPT2

Battery

Battery classLow voltage
Nominal battery voltage (V)48
Battery typeAGM, Flooded, Lithium-ion, Self-Defined
Battery voltage range (V)42-63
BMS communicationRS485
Bulk charging voltage (V)56.4
Charge algorithmThree-Stage: Boost CC, Boost CV, Float
Floating charge voltage (V)54
Max AC charge current (A)240
Max charge current (A)240
Max solar charge current (A)240
Number of battery inputs1
Pass through without batteryYes
Approved battery familiesFelicity

Protection

AC short circuit protectionYes
IP ratingIP21
Overload protectionYes
Overload trip time over 105pct load (s)10.5
Overload trip time over 120pct load (s)7.5
Overload trip time over 150pct load (s)5.5
Overload trip time over 200pct load (s)0.2
ProtectionOverload Protection, Over Temperature Protection, Short Circuit Protection
Surge duration (s)5
Surge power multiple2

Communication

DisplayLCD

General

Rated power (kVA)12
Rated power (kW)12
CoolingAir Cooling
Dimension (mm)476 x 141 x 634
High line reconnect (V)270
Input voltage range apl (V)90-280
Input voltage range UPS (V)170-280
Input voltage range (V)90-280
Low line reconnect apl (V)100
Low line reconnect UPS (V)180
Max efficiency (%)93
Motor start capableYes
Operating temperature (°C)-10 to 50
Package dimension (mm)726 x 258 x 594
Package weight (kg)28.7
Package volume m30.117
Hs code85044090
Parallel units6
Safety standardIEC 62109-1, IEC 62109-2
Startup voltage (V)100
Storage temperature (°C)-15 to 60
TopologyHigh-Frequency
Transfer time (ms)50
WaveformPure sine wave
Weight (kg)26.8

Download center

Reviews

No reviews yet.

Log in to write a review

See also

Felicity IVEM 24V II inverter off-grid low voltage single phaseIVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltagePrice1,265 SARDetails
Felicity IVEM 48V inverter off-grid low voltage single phaseIVEM 48VTypeInverterGridOff-gridPhaseSingle phaseCapacity5 kW6 kW8 kWBatteryLow voltagePrice2,634 SARDetails
Deye Off-grid inverter low voltage single phaseOG02LP1TypeInverterGridOff-gridPhaseSingle phaseCapacity6 kWBatteryLow voltagePrice2,398 SARDetails