ATOM
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity0.6 kVA
Price—
Details
AXPERT MAX II TWIN
12 kW across two outputs with the heavier 200 A charger, the fastest-charging MAX II.
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC input voltage (V) | 230 |
| DC offset mv | 100 |
| Dimension (mm) | 503.6 x 158.4 x 530.8 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 11 |
| Rated power (kW) | 11 |
| AC input voltage (V) | 230 |
| DC offset mv | 100 |
| Dimension (mm) | 503.6 x 158.4 x 530.8 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC input voltage (V) | 230 |
| Dimension (mm) | 503.6 x 158.4 x 530.8 |
| Grid frequency (Hz) | 50/60 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | USB/RS232/RS485/WIFI/Dry-contact |
| DC offset mv | 100 |
| Dimension (mm) | 503.6 x 158.4 x 530.8 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| High DC input recovery (V) | 64 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Low DC cutoff voltage (V) | 44 |
| Low line disconnect apl (V) | 90 |
| Low line disconnect UPS (V) | 170 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Low line reconnect UPS (V) | 180 |
| Max AC charge current (A) | 120 |
| Max AC input current (A) | 60 |
| Max AC input voltage (V) | 300 |
| Max charge current (A) | 150 |
| Max efficiency (%) | 93 |
| Max PV input current (A) | 27 |
| Max PV input power (kW) | 11 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 150 |
| MPPT voltage range (V) | 90-450 |
| No load current (A) | 2 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 66 |
| Parallel units | 6 |
| Relative humidity (%) | 5-95 |
| Safety standard | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 |
| Solar charger type | MPPT |
| Startup voltage (V) | 46 |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 16 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 20 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 11 |
| Rated power (kW) | 11 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | USB/RS232/RS485/WIFI/Dry-contact |
| DC offset mv | 100 |
| Dimension (mm) | 503.6 x 158.4 x 530.8 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| High DC input recovery (V) | 61 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Low DC cutoff voltage (V) | 44 |
| Low line disconnect apl (V) | 90 |
| Low line disconnect UPS (V) | 170 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Low line reconnect UPS (V) | 180 |
| Max AC charge current (A) | 150 |
| Max AC input current (A) | 60 |
| Max AC input voltage (V) | 300 |
| Max charge current (A) | 150 |
| Max efficiency (%) | 93 |
| Max PV input current (A) | 27 |
| Max PV input power (kW) | 13 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 150 |
| MPPT voltage range (V) | 90-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 63 |
| Parallel units | 6 |
| Relative humidity (%) | 5-95 |
| Safety standard | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 |
| Solar charger type | MPPT |
| Startup voltage (V) | 46 |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 22 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 20 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | USB/RS232/RS485/WIFI/Dry-contact |
| Dimension (mm) | 503.6 x 158.4 x 530.8 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 200 |
| Max charge current (A) | 200 |
| Max efficiency (%) | 93 |
| Max PV input current (A) | 27-40 |
| Max PV input power (kW) | 18 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 200 |
| MPPT voltage range (V) | 90-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 63 |
| Parallel units | 6 |
| Relative humidity (%) | 5-95 |
| Safety standard | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 24 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 20 |
ATOM
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity0.6 kVA
Price—
Details
ATOM LOBO
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT IND
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING II
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING II TWIN
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details