Home Products Deye Inverter Hybrid
A 40 kW three-phase hybrid for a commercial roof or a small industrial site, running a high-voltage battery bank. It carries four MPP trackers where the 35 kW below it has three, so a larger or more broken-up array can be split across more strings.
AC output voltage (V) 220/380, 230/400 Battery type Lithium-ion IP rating IP65 Max charge current (A) 50+50 Max efficiency (%) 97.6 Max PV input power (kW) 64 Max PV voltage (V) 1000 MPPT count 4
All specifications 77 AC AC output voltage (V) 220/380, 230/400 Grid type Hybrid Phase Three phase AC couple support Yes AC grid connection type 3L+N+PE AC voltage tolerance un 0.85-1.1 Grid frequency (Hz) 50/45-55, 60/55-65 Grid regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 Max AC passthrough (A) 200 Max apparent power (kVA) 44 Max output current (A) 66.7/63.8 Power factor adjustable range 0.8 leading to 0.8 lagging Rated AC output current (A) 60.7/58 THD (%) 3 Unbalanced output (%) 100
PV and DC DC component monitoring Yes DC injection current pct of in 0.5 DC reverse polarity protection Yes DC switch Yes Max PV access power (kW) 80 Max PV input current (A) 36+36+36+36 Max PV input power (kW) 64 Max PV voltage (V) 1000 Monitor module GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) MPPT count 4 MPPT efficiency (%) 99 MPPT voltage range (V) 150-850 Overvoltage category DC II Rated PV input voltage (V) 600 Strings per MPPT 2+2+2+2 Surge protection level DC II
Battery Battery class High voltage Battery parallel support Yes Battery type Lithium-ion Battery voltage range (V) 160-800 Charge algorithm Self-adaption to BMS Charge discharge time periods 6 Max charge current (A) 50+50 Max discharge current (A) 50+50 Number of battery inputs 2 Approved battery families Deye, Dyness, UZ, Shoto, Pylontech, BYD
Protection AC output overcurrent protection Yes AC output overvoltage protection Yes AC short circuit protection Yes AFCI protection Optional Anti islanding protection Yes Insulation resistance monitoring Yes IP rating IP65 Max short circuit current (A) 55+55+55+55 Overvoltage category AC III Surge duration (s) 10 Surge power multiple 1.5 Surge protection level AC II Thermal protection Yes
Communication Communication interface RS485, RS232, CAN Display LCD, LED Grid monitoring Yes Residual current monitoring Yes
General Rated power (kW) 40 Cooling Air Cooling Derating start temp (°C) 45 Dimension (mm) 527 x 294 x 894 European efficiency (%) 97.0 Generator support Yes (Diesel) Max altitude (m) 2000 Max efficiency (%) 97.6 Max inverter backfeed current (A) 0 Noise (dB) 65 Operating temperature (°C) -40 to 60 Package weight (kg) 103.5 Parallel units 10 Relative humidity (%) 0-100 Safety standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 Startup voltage (V) 180 Topology Non-Isolated Warranty (years) 5 Weight (kg) 80
IVEM 24V II Type Inverter Grid Off-grid Phase Single phase Capacity 4 kW Battery Low voltage IVEM 48V II Type Inverter Grid Off-grid Phase Single phase Capacity 6 kW 8 kW 12 kW Battery Low voltage T-REX Type Inverter Grid Hybrid Phase Three phase Capacity 10 kW 25 kW 29.9 kW 30 kW 40 kW 50 kW Battery High voltage ICON Type Inverter Grid Off-grid Phase Single phase Capacity 1.1 kVA Battery Low voltage OPTIMUS Type Inverter Grid Off-grid Phase Single phase Capacity 1.1 kVA 1.6 kVA Battery Low voltage AXPERT KING II TWIN 5G HELIUS Type Inverter Grid Off-grid Phase Single phase Capacity 6.2 kW Battery Low voltage