G01P3
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
SG01LP1
An 8 kW single-phase hybrid for a large home on a 48 V battery, charging at up to 190 A.
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kW) | 8 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kW) | 12 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kW) | 14 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Single phase |
| Rated power (kW) | 16 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery parallel support | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| Charge algorithm | Self-adaption to BMS |
| Charge discharge time periods | 6 |
| Communication interface | RS485, CAN, WIFI |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 330 x 232 x 580 |
| Display | LCD |
| European efficiency (%) | 96.5 |
| Generator support | Yes (Diesel) |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC passthrough (A) | 50 |
| Max altitude (m) | 2000 |
| Max apparent power (kVA) | 8.8 |
| Max charge current (A) | 190 |
| Max discharge current (A) | 190 |
| Max efficiency (%) | 97.6 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 40/38.3 |
| Max PV access power (kW) | 16 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 12.8 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 34+34 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 150-425 |
| Noise (dB) | 30 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -40 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Parallel units | 16 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 36.4/34.8 |
| Rated PV input voltage (V) | 370 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Warranty (years) | 5 |
| Weight (kg) | 24.9 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kW) | 8 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery parallel support | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| Charge algorithm | Self-adaption to BMS |
| Charge discharge time periods | 6 |
| Communication interface | RS485, CAN, WIFI |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 330 x 232 x 580 |
| Display | LCD |
| European efficiency (%) | 96.5 |
| Generator support | Yes (Diesel) |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC passthrough (A) | 50 |
| Max altitude (m) | 2000 |
| Max apparent power (kVA) | 8.8 |
| Max charge current (A) | 190 |
| Max discharge current (A) | 190 |
| Max efficiency (%) | 97.6 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 40/38.3 |
| Max PV access power (kW) | 16 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 12.8 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 34+34 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 150-425 |
| Noise (dB) | 30 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -40 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Parallel units | 16 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 36.4/34.8 |
| Rated PV input voltage (V) | 370 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Warranty (years) | 5 |
| Weight (kg) | 24.9 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kW) | 12 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery parallel support | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| Charge algorithm | Self-adaption to BMS |
| Charge discharge time periods | 6 |
| Communication interface | RS485, CAN, WIFI |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 464 x 282 x 763 |
| Display | LCD |
| European efficiency (%) | 96.5 |
| Generator support | Yes (Diesel) |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, NRS 097 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC passthrough (A) | 100 |
| Max altitude (m) | 2000 |
| Max apparent power (kVA) | 13.2 |
| Max charge current (A) | 220 |
| Max discharge current (A) | 220 |
| Max efficiency (%) | 97.6 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 60/57.4 |
| Max PV access power (kW) | 24 |
| Max PV input current (A) | 32+32+32 |
| Max PV input power (kW) | 19.2 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 60+60+60 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 3 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 150-425 |
| Noise (dB) | 50 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Parallel units | 16 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 54.5/52.2 |
| Rated PV input voltage (V) | 370 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Warranty (years) | 5/10 |
| Weight (kg) | 52 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kW) | 14 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery parallel support | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| Charge algorithm | Self-adaption to BMS |
| Charge discharge time periods | 6 |
| Communication interface | RS485, CAN, WIFI |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 464 x 282 x 763 |
| Display | LCD |
| European efficiency (%) | 96.5 |
| Generator support | Yes (Diesel) |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, NRS 097 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC passthrough (A) | 100 |
| Max altitude (m) | 2000 |
| Max apparent power (kVA) | 15.4 |
| Max charge current (A) | 250 |
| Max discharge current (A) | 250 |
| Max efficiency (%) | 97.6 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 70/67 |
| Max PV access power (kW) | 28 |
| Max PV input current (A) | 32+32+32 |
| Max PV input power (kW) | 22.4 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 60+60+60 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 3 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 150-425 |
| Noise (dB) | 50 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Parallel units | 16 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 63.6/60.9 |
| Rated PV input voltage (V) | 370 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Warranty (years) | 5/10 |
| Weight (kg) | 52 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kW) | 16 |
| AC couple support | Yes |
| AC grid connection type | L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery parallel support | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| Charge algorithm | Self-adaption to BMS |
| Charge discharge time periods | 6 |
| Communication interface | RS485, CAN, WIFI |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 464 x 282 x 763 |
| Display | LCD |
| European efficiency (%) | 96.5 |
| Generator support | Yes (Diesel) |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, NRS 097 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC passthrough (A) | 100 |
| Max altitude (m) | 2000 |
| Max apparent power (kVA) | 17.6 |
| Max charge current (A) | 290 |
| Max discharge current (A) | 290 |
| Max efficiency (%) | 97.6 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 80/76.5 |
| Max PV access power (kW) | 32 |
| Max PV input current (A) | 32+32+32 |
| Max PV input power (kW) | 25.6 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 60+60+60 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 3 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 150-425 |
| Noise (dB) | 50 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Parallel units | 16 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 72.7/69.6 |
| Rated PV input voltage (V) | 370 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 125 |
| Strings per MPPT | 2+2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Warranty (years) | 5/10 |
| Weight (kg) | 52 |
G01P3
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
G02P1
TypeInverterGridOn-gridPhaseSingle phase
Capacity
Price—
Details
G03
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
G04
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
G04
TypeInverterGridOn-gridPhaseSingle phase
Capacity
Price—
Details
G04P1
TypeInverterGridOn-gridPhaseSingle phase
Capacity
Price—
Details