Home Products Deye Inverter Hybrid
A 3 kW single-phase hybrid built for a 24 V battery bank rather than a 48 V one — a small system for a flat, cabin or shop, and a different machine from the 48 V models.
AC output voltage (V) 220/230 Battery type Lead-acid, Lithium-ion IP rating IP65 Max charge current (A) 140 Max efficiency (%) 97.6 Max PV input power (kW) 4.8 Max PV voltage (V) 500 MPPT count 1
All specifications 75 AC AC output voltage (V) 220/230 Grid type Hybrid Phase Single phase AC couple support Yes AC grid connection type L+N+PE AC voltage tolerance un 0.85-1.1 Grid frequency (Hz) 50/45-55, 60/55-65 Grid regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 Max AC passthrough (A) 35 Max apparent power (kVA) 3.3 Max output current (A) 15/14.3 Power factor adjustable range 0.8 leading to 0.8 lagging Rated AC output current (A) 13.6/13 THD (%) 3
PV and DC DC component monitoring Yes DC injection current pct of in 0.5 DC reverse polarity protection Yes DC switch Yes Max PV access power (kW) 6 Max PV input current (A) 13 Max PV input power (kW) 4.8 Max PV voltage (V) 500 Monitor module GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) MPPT count 1 MPPT efficiency (%) 99 MPPT voltage range (V) 150-425 Overvoltage category DC II Rated PV input voltage (V) 370 Strings per MPPT 1 Surge protection level DC II
Battery Battery class Low voltage Nominal battery voltage (V) 24 Battery parallel support Yes Battery type Lead-acid, Lithium-ion Battery voltage range (V) 20-30 Charge algorithm Self-adaption to BMS Charge discharge time periods 6 Max charge current (A) 140 Max discharge current (A) 140 Number of battery inputs 1 Approved battery families Deye, Dyness, Pylontech, BYD, LG, FinDreams, Weco, Alpha ESS, Hubble, Freedom Won, Shoto, Sunwoda, Jinko, Narada, Vision, Wattsonic, Sacred Sun, GenixGreen, ACE
Protection AC output overcurrent protection Yes AC output overvoltage protection Yes AC short circuit protection Yes AFCI protection Optional Anti islanding protection Yes Insulation resistance monitoring Yes IP rating IP65 Max short circuit current (A) 17 Overvoltage category AC III Surge duration (s) 10 Surge power multiple 2 Surge protection level AC II Thermal protection Yes
Communication Communication interface RS485, RS232, CAN Display LCD Residual current monitoring Yes
General Rated power (kW) 3 Cooling Nature Derating start temp (°C) 45 Dimension (mm) 330 x 228 x 433 European efficiency (%) 96.5 Generator support Yes (Diesel) Max altitude (m) 2000 Max efficiency (%) 97.6 Max inverter backfeed current (A) 0 Noise (dB) 30 Operating temperature (°C) -40 to 60 Parallel units 16 Relative humidity (%) 0-100 Safety standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 Startup voltage (V) 125 Topology Non-Isolated Warranty (years) 5/10 Weight (kg) 17
IVEM 24V II Type Inverter Grid Off-grid Phase Single phase Capacity 4 kW Battery Low voltage IVEM 48V II Type Inverter Grid Off-grid Phase Single phase Capacity 6 kW 8 kW 12 kW Battery Low voltage T-REX Type Inverter Grid Hybrid Phase Three phase Capacity 10 kW 25 kW 29.9 kW 30 kW 40 kW 50 kW Battery High voltage ICON Type Inverter Grid Off-grid Phase Single phase Capacity 1.1 kVA Battery Low voltage OPTIMUS Type Inverter Grid Off-grid Phase Single phase Capacity 1.1 kVA 1.6 kVA Battery Low voltage AXPERT KING II TWIN 5G HELIUS Type Inverter Grid Off-grid Phase Single phase Capacity 6.2 kW Battery Low voltage