- Home
- Products
- Deye
- Inverter
- On-grid
A 3.3 kW single-phase on-grid inverter for a modest home array, on-grid only.
| AC output voltage (V) | 220/230 |
|---|
| IP rating | IP65 |
|---|
| Max efficiency (%) | 97.5 |
|---|
| Max PV input power (kW) | 4.3 |
|---|
| Max PV voltage (V) | 550 |
|---|
| MPPT count | 1 |
|---|
| MPPT voltage range (V) | 70-500 |
|---|
| Warranty (years) | 5 |
|---|
All specifications65
AC
| AC output voltage (V) | 220/230 |
|---|
| Grid type | On-grid |
|---|
| Phase | Single phase |
|---|
| AC grid connection type | L+N+PE |
|---|
| AC voltage tolerance un | 0.85-1.1 |
|---|
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
|---|
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, G98, G99, VDE-AR-N 4105 |
|---|
| Max apparent power (kVA) | 3.63 |
|---|
| Max output current (A) | 16.5/15.8 |
|---|
| Max output fault current (A) | 28.8 |
|---|
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
|---|
| Rated AC output current (A) | 15/14.4 |
|---|
| THD (%) | 3 |
|---|
PV and DC
| DC component monitoring | Yes |
|---|
| DC injection current pct of in | 0.5 |
|---|
| DC reverse polarity protection | Yes |
|---|
| DC switch | Yes |
|---|
| Max PV input current (A) | 20 |
|---|
| Max PV input power (kW) | 4.3 |
|---|
| Max PV voltage (V) | 550 |
|---|
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
|---|
| MPPT count | 1 |
|---|
| MPPT efficiency (%) | 99 |
|---|
| MPPT full load voltage range (V) | 330-500 |
|---|
| MPPT voltage range (V) | 70-500 |
|---|
| Overvoltage category DC | II |
|---|
| Rated PV input voltage (V) | 360 |
|---|
| String monitoring | Optional |
|---|
| Strings per MPPT | 1 |
|---|
| Surge protection level DC | II |
|---|
Protection
| AC output overcurrent protection | Yes |
|---|
| AC output overvoltage protection | Yes |
|---|
| AC short circuit protection | Yes |
|---|
| AFCI protection | Optional |
|---|
| Anti islanding protection | Yes |
|---|
| Insulation resistance monitoring | Yes |
|---|
| IP rating | IP65 |
|---|
| Max output overcurrent protection (A) | 35.8 |
|---|
| Max short circuit current (A) | 30 |
|---|
| Overload protection | Yes |
|---|
| Overvoltage category AC | III |
|---|
| Surge protection level AC | II |
|---|
| Thermal protection | Yes |
|---|
Communication
| Communication interface | RS485, RS232 |
|---|
| Grid monitoring | Yes |
|---|
| Residual current monitoring | Yes |
|---|
General
| Rated power (kW) | 3.3 |
|---|
| Anti PID | Optional |
|---|
| Cooling | Nature |
|---|
| Derating start temp (°C) | 45 |
|---|
| Dimension (mm) | 280 x 171.5 x 272.5 |
|---|
| European efficiency (%) | 97.0 |
|---|
| Max altitude (m) | 2000 |
|---|
| Max efficiency (%) | 97.5 |
|---|
| Max inverter backfeed current (A) | 0 |
|---|
| Noise (dB) | 35 |
|---|
| Operating temperature (°C) | -25 to 65 |
|---|
| Relative humidity (%) | 0-100 |
|---|
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
|---|
| Startup voltage (V) | 80 |
|---|
| Topology | Non-Isolated |
|---|
| Vsg support | Yes |
|---|
| Warranty (years) | 5 |
|---|
| Weight (kg) | 5.6 |
|---|
| Zero export support | Yes |
|---|


IVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltage

IVEM 48V IITypeInverterGridOff-gridPhaseSingle phaseCapacity6 kW8 kW12 kWBatteryLow voltage

T-REXTypeInverterGridHybridPhaseThree phaseCapacity10 kW25 kW29.9 kW30 kW40 kW50 kWBatteryHigh voltage

ICONTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVABatteryLow voltage

OPTIMUSTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVA1.6 kVABatteryLow voltage

AXPERT KING II TWIN 5G HELIUSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltage