IVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltagePriceComing soon1,239 AEDDetails






Coming in 4 weeks
| AC output voltage (V) | 120/240 |
|---|---|
| Phase | Split phase 120/240 |
| Battery type | Lead-acid, Lithium-ion |
| IP rating | IP65 |
| Max charge current (A) | 120 |
| Max efficiency (%) | 97.6 |
| Max PV input power (kW) | 7.5 |
| Max PV voltage (V) | 500 |
| AC output voltage (V) | 120/240 |
|---|---|
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 |
| Max AC input current (A) | 40 |
| Max AC output power (kW) | 5.5 |
| Max AC passthrough (A) | 40 |
| Max output current (A) | 22.9 |
| Output frequency (Hz) | 50/60 |
| Power factor | 0.99 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 20.8 |
| THD (%) | 3 |
| Max PV input current (A) | 13+13 |
|---|---|
| Max PV input power (kW) | 7.5 |
| Max PV voltage (V) | 500 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 290-425 |
| MPPT voltage range (V) | 120-425 |
| PV voltage working range (V) | 90-500 |
| Rated PV input voltage (V) | 380 |
| Strings per MPPT | 1+1 |
| Battery class | Low voltage |
|---|---|
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Max charge current (A) | 120 |
| Max charge power (kW) | 5 |
| Max discharge current (A) | 120 |
| Max discharge power (kW) | 5 |
| Number of battery inputs | 1 |
| Approved battery families | Felicity |
| AC short circuit protection | Yes |
|---|---|
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max short circuit current (A) | 17+17 |
| Overload protection | Yes |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Communication interface | RS485, RS232 |
|---|---|
| Display | LCD, LED |
| Rated power (kVA) | 5 |
|---|---|
| Rated power (kW) | 5 |
| Cooling | Air Cooling |
| Dimension (mm) | 430 x 243 x 654 |
| European efficiency (%) | 97 |
| Max altitude (m) | 2000 |
| Max efficiency (%) | 97.6 |
| Noise (dB) | 35 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
No reviews yet.
Log in to write a review

IVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltagePriceComing soon1,239 AEDDetails

IVEM 48V IITypeInverterGridOff-gridPhaseSingle phaseCapacity6 kW8 kW12 kWBatteryLow voltagePriceComing soon1,492 AEDDetails

T-REXTypeInverterGridHybridPhaseThree phaseCapacity10 kW25 kW29.9 kW30 kW40 kW50 kWBatteryHigh voltagePriceComing soon17,944 AEDDetails
ICONTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVABatteryLow voltagePriceComing soon709 AEDDetails

OPTIMUSTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVA1.6 kVABatteryLow voltagePriceComing soon474 AEDDetails

AXPERT KING II TWIN 5G HELIUSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltagePriceComing soon1,844 AEDDetails