AI100 48V
TypeInverterGridStoragePhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVAM 48V
6 kW off-grid at 13.5 kg, IP65-rated with a 135 A charge limit and 97.6% efficiency — a whole-home inverter for a typical house.
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, CAN |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 320 x 183.2 x 435 |
| Display | LCD, LED |
| European efficiency (%) | 96.5 |
| Grid frequency (Hz) | 50/60 |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 6 |
| Max AC passthrough (A) | 35 |
| Max altitude (m) | 3000 |
| Max charge current (A) | 135 |
| Max charge power (kW) | 6 |
| Max discharge current (A) | 135 |
| Max discharge power (kW) | 6 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 26.1 |
| Max PV access power (kW) | 12 |
| Max PV input current (A) | 20+20 |
| Max PV input power (kW) | 9.6 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 27+27 |
| Monitor module | WiFi/LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 300-425 |
| MPPT voltage range (V) | 90-425 |
| Noise (dB) | 55 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 412 x 270 x 532 |
| Package weight (kg) | 15.4 |
| Parallel units | 6 |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection |
| PV voltage working range (V) | 90-500 |
| Rated PV input voltage (V) | 370 |
| Relative humidity (%) | 0-100 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 120 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Warranty (years) | 5 |
| Waveform | Pure sine wave |
| Weight (kg) | 13.5 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, CAN |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 594 x 203 x 385 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 8 |
| Max AC passthrough (A) | 50 |
| Max charge current (A) | 190 |
| Max charge power (kW) | 8 |
| Max discharge current (A) | 190 |
| Max discharge power (kW) | 8 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 34.8 |
| Max PV input current (A) | 27+27 |
| Max PV input power (kW) | 16 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 40+40 |
| Monitor module | WiFi/LAN (optional) |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 200-425 |
| MPPT voltage range (V) | 90-425 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 752 x 348 x 507 |
| Package weight (kg) | 25.4 |
| Parallel units | 6 |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection |
| PV voltage working range (V) | 90-500 |
| Rated PV input voltage (V) | 370 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 120 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Warranty (years) | 5 |
| Waveform | Pure sine wave |
| Weight (kg) | 21.4 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, CAN |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 594 x 203 x 385 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC input current (A) | 60 |
| Max AC output power (kW) | 10 |
| Max AC passthrough (A) | 60 |
| Max apparent power (kVA) | 10 |
| Max charge current (A) | 210 |
| Max charge power (kW) | 10 |
| Max discharge current (A) | 210 |
| Max discharge power (kW) | 10 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 43.5 |
| Max PV access power (kW) | 20 |
| Max PV input current (A) | 32+32 |
| Max PV input power (kW) | 20 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 48+48 |
| Monitor module | WiFi/LAN (optional) |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 200-425 |
| MPPT voltage range (V) | 90-425 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 752 x 348 x 507 |
| Package weight (kg) | 25.4 |
| Parallel units | 6 |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection |
| PV voltage working range (V) | 90-500 |
| Rated PV input voltage (V) | 370 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 120 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| Topology | Non-Isolated |
| Warranty (years) | 5 |
| Waveform | Pure sine wave |
| Weight (kg) | 21.4 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 12 |
| Rated power (kW) | 12 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, CAN |
| Cooling | Air Cooling |
| DC switch | Yes |
| Dimension (mm) | 594 x 203 x 385 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC input current (A) | 66 |
| Max AC output power (kW) | 12 |
| Max AC passthrough (A) | 60 |
| Max apparent power (kVA) | 12 |
| Max charge current (A) | 250 |
| Max charge power (kW) | 12 |
| Max discharge current (A) | 250 |
| Max discharge power (kW) | 12 |
| Max efficiency (%) | 97.6 |
| Max generator input current (A) | 60 |
| Max output current (A) | 52.2 |
| Max PV access power (kW) | 24 |
| Max PV input current (A) | 32+32 |
| Max PV input power (kW) | 24 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 48+48 |
| Monitor module | WiFi/LAN (optional) |
| MPPT count | 2 |
| MPPT full load voltage range (V) | 200-425 |
| MPPT voltage range (V) | 90-425 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 752 x 348 x 507 |
| Package weight (kg) | 25.4 |
| Parallel units | 6 |
| Protection | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection |
| PV voltage working range (V) | 90-500 |
| Rated PV input voltage (V) | 370 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 120 |
| Strings per MPPT | 2+2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| Topology | Non-Isolated |
| Warranty (years) | 5 |
| Waveform | Pure sine wave |
| Weight (kg) | 21.4 |
AI100 48V
TypeInverterGridStoragePhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVBM 48V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVCM 12V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity2 kW
Price—
Details
IVCM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity3.2 kW
Price—
Details
IVDM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity4.2 kW
Price—
Details
IVEM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity3 kW
Price$261.30
Details