- Home
- Products
- Felicity
- Inverter
- Off-grid








Felicity IVEM 48V Off-grid inverter 5 kW
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltageSystem48 V
Capacity5 kW6 kW8 kW
5 kW off-grid on a 220/230 V supply with a 100 A charge limit — the most common household size in the line.
| AC output voltage (V) | 230 |
|---|
| IP rating | IP21 |
|---|
| Max charge current (A) | 100 |
|---|
| Max efficiency (%) | 93 |
|---|
| Max PV input power (kW) | 6 |
|---|
| Max PV voltage (V) | 500 |
|---|
| MPPT count | 1 |
|---|
| MPPT voltage range (V) | 120-500 |
|---|
All specifications85
AC
| AC output voltage (V) | 230 |
|---|
| Grid type | Off-grid |
|---|
| Phase | Single phase |
|---|
| AC grid connection type | L+N+PE |
|---|
| AC input voltage (V) | 230 |
|---|
| Grid frequency (Hz) | 50/60 |
|---|
| High line frequency reconnect (Hz) | 63 |
|---|
| Low line frequency reconnect (Hz) | 42 |
|---|
| Max AC input voltage (V) | 280 |
|---|
| Max AC passthrough (A) | 63 |
|---|
| Output frequency (Hz) | 50/60 |
|---|
| Output voltage regulation (%) | 5 |
|---|
PV and DC
| High DC input recovery (V) | 56.4 |
|---|
| High line disconnect (V) | 280 |
|---|
| High line frequency disconnect (Hz) | 65 |
|---|
| Low DC input shutdown load over 50pct (V) | 42 |
|---|
| Low DC input shutdown load under 50pct (V) | 43 |
|---|
| Low line disconnect apl (V) | 90 |
|---|
| Low line disconnect UPS (V) | 170 |
|---|
| Low line frequency disconnect (Hz) | 40 |
|---|
| Max PV input current (A) | 20 |
|---|
| Max PV input power (kW) | 6 |
|---|
| Max PV voltage (V) | 500 |
|---|
| Monitor module | Built-In WiFi |
|---|
| MPPT count | 1 |
|---|
| MPPT voltage range (V) | 120-500 |
|---|
| PV voltage working range (V) | 120-500 |
|---|
| Strings per MPPT | 1 |
|---|
Battery
| Battery class | Low voltage |
|---|
| Nominal battery voltage (V) | 48 |
|---|
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
|---|
| Battery voltage range (V) | 42-63 |
|---|
| BMS communication | RS485 |
|---|
| Bulk charging voltage (V) | 56.4 |
|---|
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
|---|
| Floating charge voltage (V) | 54 |
|---|
| Low battery recovery load over 50pct (V) | 46 |
|---|
| Low battery recovery load under 50pct (V) | 47 |
|---|
| Max AC charge current (A) | 100 |
|---|
| Max charge current (A) | 100 |
|---|
| Max charging voltage (V) | 60 |
|---|
| Max solar charge current (A) | 100 |
|---|
| Number of battery inputs | 1 |
|---|
| Pass through without battery | Yes |
|---|
| Short circuit protection battery mode | Electronic Circuit |
|---|
| Approved battery families | Felicity |
|---|
Protection
| AC short circuit protection | Yes |
|---|
| IP rating | IP21 |
|---|
| Overload protection | Yes |
|---|
| Overload trip time over 105pct load (s) | 10.5 |
|---|
| Overload trip time over 150pct load (s) | 5.5 |
|---|
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
|---|
| Short circuit protection line mode | Circuit Breaker |
|---|
| Surge duration (s) | 5 |
|---|
| Surge power multiple | 2 |
|---|
Communication
General
| Rated power (kVA) | 5 |
|---|
| Rated power (kW) | 5 |
|---|
| Cooling | Air Cooling |
|---|
| Dimension (mm) | 320 x 129 x 415 |
|---|
| High line reconnect (V) | 270 |
|---|
| Input voltage range apl (V) | 90-280 |
|---|
| Input voltage range UPS (V) | 170-280 |
|---|
| Input voltage range (V) | 90-280 |
|---|
| Input voltage waveform | Sinusoidal (utility or generator) |
|---|
| Line mode efficiency (%) | 95 |
|---|
| Low line reconnect apl (V) | 100 |
|---|
| Low line reconnect UPS (V) | 180 |
|---|
| Max efficiency (%) | 93 |
|---|
| Motor start capable | Yes |
|---|
| Operating temperature (°C) | 0-55 |
|---|
| Package dimension (mm) | 494 x 202 x 399 |
|---|
| Package weight (kg) | 13.2 |
|---|
| Package volume m3 | 0.039815 |
|---|
| Hs code | 85044090 |
|---|
| Parallel units | 12 |
|---|
| Safety standard | IEC 62109-1, IEC 62109-2 |
|---|
| Startup voltage (V) | 125 |
|---|
| Storage temperature (°C) | -15 to 60 |
|---|
| Topology | High-Frequency |
|---|
| Transfer time apl (ms) | 20 |
|---|
| Transfer time (ms) | 50 |
|---|
| Transfer time UPS (ms) | 10 |
|---|
| Waveform | Pure sine wave |
|---|
| Weight (kg) | 11.2 |
|---|


IVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltage

IVEM 48V IITypeInverterGridOff-gridPhaseSingle phaseCapacity6 kW8 kW12 kWBatteryLow voltage

T-REXTypeInverterGridHybridPhaseThree phaseCapacity10 kW25 kW29.9 kW30 kW40 kW50 kWBatteryHigh voltage

ICONTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVABatteryLow voltage

OPTIMUSTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVA1.6 kVABatteryLow voltage

AXPERT KING II TWIN 5G HELIUSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltage