- Home
- Products
- Growatt
- Inverter
- Hybrid




Growatt WIT HU Hybrid inverter 4 kW
TypeInverterGridHybridPhaseThree phaseBatteryLow voltageSystem48 V
Capacity4 kW5 kW6 kW8 kW10 kW12 kW15 kW
Listed at 4 kW on a 1000 V array with a low-voltage battery — the smallest three-phase WIT.
| AC output voltage (V) | 220/380, 230/400 |
|---|
| Battery type | Lead-acid, Lithium-ion |
|---|
| IP rating | IP66 |
|---|
| Max charge current (A) | 110 |
|---|
| Max efficiency (%) | 97.60 |
|---|
| Max PV input power (kW) | 6.4 |
|---|
| Max PV voltage (V) | 1000 |
|---|
| MPPT count | 1 |
|---|
All specifications60
AC
| AC output voltage (V) | 220/380, 230/400 |
|---|
| Grid type | Hybrid |
|---|
| Phase | Three phase |
|---|
| AC grid connection type | 3P3W+PE/3P4W+PE |
|---|
| Grid frequency (Hz) | 50/60 |
|---|
| Max apparent power (kVA) | 4.4 |
|---|
| Max output current (A) | 6.7 |
|---|
| Output frequency (Hz) | 50/60 |
|---|
| Power factor adjustable range | -1 to 1 |
|---|
| THD (%) | 3 |
|---|
PV and DC
| DC reverse polarity protection | Yes |
|---|
| DC switch | Yes |
|---|
| Max PV input current (A) | 40 |
|---|
| Max PV input power (kW) | 6.4 |
|---|
| Max PV voltage (V) | 1000 |
|---|
| MPPT count | 1 |
|---|
| MPPT efficiency (%) | 99.90 |
|---|
| MPPT voltage range (V) | 150-850 |
|---|
| Rated PV input voltage (V) | 600 |
|---|
| String monitoring | Yes |
|---|
| Strings per MPPT | 2 |
|---|
| Surge protection level DC | II |
|---|
Battery
| Battery class | Low voltage |
|---|
| Nominal battery voltage (V) | 48 |
|---|
| Battery type | Lead-acid, Lithium-ion |
|---|
| Battery voltage range (V) | 40-60 |
|---|
| BMS communication | RS485, CAN |
|---|
| Max charge current (A) | 110 |
|---|
| Max discharge current (A) | 110 |
|---|
| Approved battery families | Growatt ARK, Growatt AXE, Growatt ALP, Growatt GBLI, Growatt Hope |
|---|
Protection
| AC short circuit protection | Yes |
|---|
| AFCI protection | Optional |
|---|
| Anti islanding protection | Yes |
|---|
| Ground fault monitoring | Yes |
|---|
| Insulation resistance monitoring | Yes |
|---|
| IP rating | IP66 |
|---|
| Max short circuit current (A) | 50 |
|---|
| Surge power (kVA) | 8 |
|---|
| Surge protection level AC | III |
|---|
Communication
| Communication interface | RS485/USB/WIFI/LAN |
|---|
| Display | OLED, LED |
|---|
| Grid monitoring | Yes |
|---|
| Residual current monitoring | Yes |
|---|
General
| Rated power (kW) | 4 |
|---|
| Anti PID | Optional |
|---|
| Cooling | Air Cooling |
|---|
| Dimension (mm) | 475 x 240 x 698 |
|---|
| European efficiency (%) | 97.00 |
|---|
| Input voltage range (V) | -15% to +10% |
|---|
| Max altitude (m) | 3000 |
|---|
| Max efficiency (%) | 97.60 |
|---|
| Noise (dB) | 50 |
|---|
| Operating temperature (°C) | -30 to 60 |
|---|
| Parallel units | 6 |
|---|
| Relative humidity (%) | 0-100 |
|---|
| Startup voltage (V) | 180 |
|---|
| Topology | Transformerless |
|---|
| Transfer time (ms) | 10 |
|---|
| Warranty (years) | 5/10 |
|---|
| Weight (kg) | 43 |
|---|


IVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltage

IVEM 48V IITypeInverterGridOff-gridPhaseSingle phaseCapacity6 kW8 kW12 kWBatteryLow voltage

T-REXTypeInverterGridHybridPhaseThree phaseCapacity10 kW25 kW29.9 kW30 kW40 kW50 kWBatteryHigh voltage

ICONTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVABatteryLow voltage

OPTIMUSTypeInverterGridOff-gridPhaseSingle phaseCapacity1.1 kVA1.6 kVABatteryLow voltage

AXPERT KING II TWIN 5G HELIUSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltage