- Home
- Products
- Voltronic
- Inverter
- Off-grid




Voltronic AXPERT MAX TWIN Off-grid inverter 8 kW
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltageSystem48 V
Capacity8 kW12 kW14.4 kW
8 kW across two outputs with a 120 A charger, for a large home.
| Max charge current (A) | 120 |
|---|
| Max efficiency (%) | 93 |
|---|
| Max PV input power (kW) | 11 |
|---|
| Max PV voltage (V) | 500 |
|---|
| MPPT voltage range (V) | 90-450 |
|---|
All specifications50
AC
| Grid type | Off-grid |
|---|
| Phase | Single phase |
|---|
| AC input voltage (V) | 230 |
|---|
| AC voltage regulation batt mode | 5 |
|---|
| Grid frequency (Hz) | 50/60 |
|---|
| High line frequency reconnect (Hz) | 63 |
|---|
| Low line frequency reconnect (Hz) | 42 |
|---|
| Max AC input current (A) | 60 |
|---|
| Max AC input voltage (V) | 300 |
|---|
| No load current (A) | 2 |
|---|
PV and DC
| DC offset mv | 100 |
|---|
| High DC input recovery (V) | 64 |
|---|
| High line disconnect (V) | 280 |
|---|
| High line frequency disconnect (Hz) | 65 |
|---|
| Low DC cutoff voltage (V) | 44 |
|---|
| Low line disconnect apl (V) | 90 |
|---|
| Low line disconnect UPS (V) | 170 |
|---|
| Low line frequency disconnect (Hz) | 40 |
|---|
| Max PV input current (A) | 27 |
|---|
| Max PV input power (kW) | 11 |
|---|
| Max PV voltage (V) | 500 |
|---|
| MPPT voltage range (V) | 90-450 |
|---|
Battery
| Battery class | Low voltage |
|---|
| Nominal battery voltage (V) | 48 |
|---|
| Floating charge voltage (V) | 54 |
|---|
| Max AC charge current (A) | 120 |
|---|
| Max charge current (A) | 120 |
|---|
| Max solar charge current (A) | 120 |
|---|
| Overcharge protection (V) | 66 |
|---|
| Solar charger type | MPPT |
|---|
| Approved battery families | Pylontech, Dyness, Weco, Soltaro |
|---|
Protection
Communication
| Communication interface | USB/RS232/RS485/WIFI/Dry-contact |
|---|
General
| Rated power (kVA) | 8 |
|---|
| Rated power (kW) | 8 |
|---|
| Dimension (mm) | 432.5 x 147.4 x 553.6 |
|---|
| High line reconnect (V) | 270 |
|---|
| Input voltage range apl (V) | 90-280 |
|---|
| Input voltage range UPS (V) | 170-280 |
|---|
| Low line reconnect apl (V) | 100 |
|---|
| Low line reconnect UPS (V) | 180 |
|---|
| Max efficiency (%) | 93 |
|---|
| Operating temperature (°C) | -10 to 50 |
|---|
| Parallel units | 6 |
|---|
| Relative humidity (%) | 5-95 |
|---|
| Safety standard | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 |
|---|
| Storage temperature (°C) | -15 to 60 |
|---|
| Transfer time (ms) | 10-20 |
|---|
| Waveform | Pure sine wave |
|---|
| Weight (kg) | 18.4 |
|---|


AXPERT KING II TWIN 5G HELIUSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltage

AXPERT KING II TWIN AGSTypeInverterGridOff-gridPhaseSingle phaseCapacity6.2 kWBatteryLow voltage

AXPERT MAX E TWIN AGSTypeInverterGridOff-gridPhaseSingle phaseCapacity11 kWBatteryLow voltage

AXPERT ULTRA SUPER DELUXE POWERTypeInverterGridOff-gridPhaseSingle phaseCapacity11 kWBatteryLow voltage

AXPERT VM II AGSTypeInverterGridOff-gridPhaseSingle phaseCapacity1.2 kW5 kWBatteryLow voltage

AXPERT VM III TWIN 5G HELIUSTypeInverterGridOff-gridPhaseSingle phaseCapacity4 kW6 kWBatteryLow voltage