ATOM
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity0.6 kVA
Price—
Details
AXPERT VM II
5 kW on a 48 V bank with a 100 A charger, the whole-home size in the VM II range.
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 3 |
| Rated power (kW) | 3 |
| AC input voltage (V) | 230 |
| Dimension (mm) | 300 x 100 x 440 |
| Grid frequency (Hz) | 50/60 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC input voltage (V) | 230 |
| Dimension (mm) | 300 x 100 x 440 |
| Grid frequency (Hz) | 50/60 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 12 |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Floating charge voltage (V) | 13.5 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 80 |
| Max charge current (A) | 80 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 2 |
| Max PV voltage (V) | 350 |
| Max solar charge current (A) | 80 |
| MPPT voltage range (V) | 60-300 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 16 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 2.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 6.5 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232 |
| Dimension (mm) | 288 x 90 x 357 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 80 |
| Max charge current (A) | 80 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 3 |
| Max PV voltage (V) | 450 |
| Max solar charge current (A) | 80 |
| MPPT voltage range (V) | 60-400 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 32 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 5 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 7.1 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 3 |
| Rated power (kW) | 3 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | USB/RS232 (optional USB/Dry-contact) |
| Dimension (mm) | 300 x 100 x 440 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 100 |
| Max charge current (A) | 100 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 4 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 100 |
| MPPT voltage range (V) | 120-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 33 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 6 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 9 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | USB/RS232 (optional USB/Dry-contact) |
| Dimension (mm) | 300 x 100 x 440 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 100 |
| Max charge current (A) | 100 |
| Max efficiency (%) | 93 |
| Max PV input power (kW) | 5 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 100 |
| MPPT voltage range (V) | 120-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 63 |
| Relative humidity (%) | 5-95 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 10 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 10 |
ATOM
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity0.6 kVA
Price—
Details
ATOM LOBO
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT IND
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING II
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING II TWIN
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details