Felicity IVPS 12V Off-grid inverter 1.5 kVA
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltageSystem12 V
Capacity0.75 kVA1.5 kVA2.5 kVA
1.5 kVA off-grid on a 12 V bank, enough to add a fan and a small fridge.
| AC output voltage (V) | 220 |
|---|
| Rated power (kW) | 1.2 |
|---|
| IP rating | IP21 |
|---|
| Max charge current (A) | 18 |
|---|
| Max efficiency (%) | 90 |
|---|
All specifications70
AC
| AC output voltage (V) | 220 |
|---|
| Grid type | Off-grid |
|---|
| Phase | Single phase |
|---|
| AC grid connection type | L+N+PE |
|---|
| AC input voltage (V) | 220 |
|---|
| Grid frequency (Hz) | 50/60 |
|---|
| High line frequency reconnect (Hz) | 63 |
|---|
| Line mode output waveform | Same As Input Waveform |
|---|
| Low line frequency reconnect (Hz) | 42 |
|---|
| Max AC input voltage (V) | 280 |
|---|
| Max AC passthrough (A) | 10 |
|---|
| Output frequency (Hz) | 50/60 |
|---|
| Output voltage regulation (%) | 5 |
|---|
PV and DC
| High DC input recovery (V) | 15.5 |
|---|
| High line disconnect (V) | 280 |
|---|
| High line frequency disconnect (Hz) | 65 |
|---|
| Low DC input shutdown load over 50pct (V) | 10.5 |
|---|
| Low DC input shutdown load under 50pct (V) | 10.75 |
|---|
| Low line disconnect apl (V) | 90 |
|---|
| Low line disconnect UPS (V) | 170 |
|---|
| Low line frequency disconnect (Hz) | 40 |
|---|
Battery
| Battery class | Low voltage |
|---|
| Nominal battery voltage (V) | 12 |
|---|
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
|---|
| Battery voltage range (V) | 10.5-15.75 |
|---|
| BMS communication | RS485 |
|---|
| Bulk charging voltage (V) | 14.4 |
|---|
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
|---|
| Floating charge voltage (V) | 13.6 |
|---|
| Low battery recovery load over 50pct (V) | 11.5 |
|---|
| Low battery recovery load under 50pct (V) | 11.75 |
|---|
| Max AC charge current (A) | 18 |
|---|
| Max charge current (A) | 18 |
|---|
| Max charging voltage (V) | 16 |
|---|
| Number of battery inputs | 1 |
|---|
| Pass through without battery | No |
|---|
| Approved battery families | Felicity |
|---|
Protection
| AC short circuit protection | Yes |
|---|
| IP rating | IP21 |
|---|
| Max output overcurrent protection (A) | 10 |
|---|
| Overload protection | Air Switch Protection |
|---|
| Overload trip time over 105pct load (s) | 10 |
|---|
| Overload trip time over 150pct load (s) | 5 |
|---|
| Protection | Over Charge Protection, Over Discharge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
|---|
| Short circuit protection line mode | Air Switch Protection |
|---|
| Surge duration (s) | 5 |
|---|
| Surge power multiple | 2 |
|---|
Communication
| Communication interface | RS232 |
|---|
| Display | LCD, LED |
|---|
General
| Rated power (kVA) | 1.5 |
|---|
| Rated power (kW) | 1.2 |
|---|
| Cooling | Air Cooling |
|---|
| High line reconnect (V) | 270 |
|---|
| Input voltage range apl (V) | 90-280 |
|---|
| Input voltage range UPS (V) | 170-280 |
|---|
| Input voltage range (V) | 90-280 |
|---|
| Input voltage waveform | Sinusoidal (utility or generator) |
|---|
| Line mode efficiency (%) | 95 |
|---|
| Low line reconnect apl (V) | 100 |
|---|
| Low line reconnect UPS (V) | 180 |
|---|
| Max efficiency (%) | 90 |
|---|
| Motor start capable | Yes |
|---|
| Operating temperature (°C) | 0-40 |
|---|
| Package dimension (mm) | 440 x 246 x 312 |
|---|
| Parallel units | 6 |
|---|
| Startup voltage (V) | 11.5 |
|---|
| Storage temperature (°C) | -15 to 60 |
|---|
| Topology | Low-Frequency (transformer-based) |
|---|
| Transfer time (ms) | 15 |
|---|
| Waveform | Pure sine wave |
|---|


IVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltage

IVEM 48VTypeInverterGridOff-gridPhaseSingle phaseCapacity5 kW6 kW8 kWBatteryLow voltage

IVEM 48V IITypeInverterGridOff-gridPhaseSingle phaseCapacity6 kW8 kW12 kWBatteryLow voltage

G01P3TypeInverterGridOn-gridPhaseThree phaseCapacity120 kW125 kW130 kW135 kW136 kW

G03TypeInverterGridOn-gridPhaseThree phaseCapacity70 kW75 kW80 kW90 kW100 kW110 kW

OG02LP1TypeInverterGridOff-gridPhaseSingle phaseCapacity6 kWBatteryLow voltage