+POWER
TypeUPS
Capacity
Price—
Details
FORTRESS
60 kVA with an 18 A adjustable charger, the entry size — a floor of equipment or a small production line.
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 60 |
| Rated power (kW) | 60 |
| AC mode efficiency (%) | 95 |
| Battery quantity | 32-40 |
| Dimension (mm) | 320 x 1000 x 800 |
| Eco mode efficiency (%) | 98 |
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 80 |
| Rated power (kW) | 80 |
| AC mode efficiency (%) | 96 |
| Battery quantity | 32-40 |
| Dimension (mm) | 430 x 1000 x 1200 |
| Eco mode efficiency (%) | 99 |
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 100 |
| Rated power (kW) | 100 |
| AC mode efficiency (%) | 95.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 430 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 120 |
| Rated power (kW) | 120 |
| AC mode efficiency (%) | 95.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 430 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 180 |
| Rated power (kW) | 180 |
| AC mode efficiency (%) | 95.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 200 |
| Rated power (kW) | 200 |
| AC mode efficiency (%) | 95.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 240 |
| Rated power (kW) | 240 |
| AC mode efficiency (%) | 95.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1100 x 1475 |
| Eco mode efficiency (%) | 98.5 |
| Device class | UPS |
|---|---|
| Phase | Three-Phase |
| Rated power (kVA) | 300 |
| Rated power (kW) | 300 |
| AC mode efficiency (%) | 95.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1100 x 1475 |
| Eco mode efficiency (%) | 98.5 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 60 |
| Rated power (kW) | 60 |
| AC mode efficiency (%) | 95 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 94 |
| Battery quantity | 32-40 |
| Dimension (mm) | 320 x 1000 x 800 |
| Eco mode efficiency (%) | 98 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 184-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 18 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 320 x 1000 x 800 |
| Package weight (kg) | 94 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 94 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 80 |
| Rated power (kW) | 80 |
| AC mode efficiency (%) | 96 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 95.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 430 x 1000 x 1200 |
| Eco mode efficiency (%) | 99 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 190-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 18 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 430 x 1000 x 1200 |
| Package weight (kg) | 125 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 125 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 100 |
| Rated power (kW) | 100 |
| AC mode efficiency (%) | 95.5 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 94.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 430 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 184-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 24 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 430 x 1000 x 1200 |
| Package weight (kg) | 169 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 169 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 120 |
| Rated power (kW) | 120 |
| AC mode efficiency (%) | 95.5 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 94.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 430 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 184-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 36 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 430 x 1000 x 1200 |
| Package weight (kg) | 169 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 169 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 180 |
| Rated power (kW) | 180 |
| AC mode efficiency (%) | 95.5 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 94.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 184-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 54 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 600 x 1000 x 1200 |
| Package weight (kg) | 249 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 249 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 200 |
| Rated power (kW) | 200 |
| AC mode efficiency (%) | 95.5 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 94.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1000 x 1200 |
| Eco mode efficiency (%) | 98.5 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 184-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 54 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 600 x 1000 x 1200 |
| Package weight (kg) | 249 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 249 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 240 |
| Rated power (kW) | 240 |
| AC mode efficiency (%) | 95.5 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 94.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1100 x 1475 |
| Eco mode efficiency (%) | 98.5 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 184-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 72 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 600 x 1100 x 1475 |
| Package weight (kg) | 360 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 360 |
| Device class | UPS |
|---|---|
| Nominal battery voltage (V) | ±192 / ±240 |
| Phase | Three-Phase |
| Rated power (kVA) | 300 |
| Rated power (kW) | 300 |
| AC mode efficiency (%) | 95.5 |
| AC voltage regulation batt mode | 1 |
| Battery mode efficiency (%) | 94.5 |
| Battery quantity | 32-40 |
| Dimension (mm) | 600 x 1100 x 1475 |
| Eco mode efficiency (%) | 98.5 |
| Float charge voltage per cell (V) | 2.28 |
| Harmonic distortion (%) | 2-4 |
| Humidity (%) | 0-95 |
| Input frequency range (Hz) | 40-70 |
| Input voltage range (V) | 110-300 @ 50% load; 184-276 @ 100% load |
| IP rating | IP20 |
| Max charging current (A) | 90 |
| Nominal input voltage (V) | 380/400/415 |
| Operating temperature (°C) | 0 to 40 |
| Output voltage (V) | 380/400/415 |
| Overload capacity | ≤110%: 60 min; 111-125%: 10 min; 126-150%: 1 min; >150%: 200 ms |
| Package dimension (mm) | 600 x 1100 x 1475 |
| Package weight (kg) | 396 |
| Power factor | 1.0 |
| Safety standard | IEC/EN 62040-1, IEC/EN 62040-2 Category C3 |
| Synchronized frequency range (Hz) | 46-54 or 56-64 |
| Transfer time (ms) | 0 |
| Weight (kg) | 396 |