ATOM
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity0.6 kVA
Price—
Details
AXPERT IND
2.5 kW, enough for lights, a fridge and general sockets in a flat.
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 330 x 104 x 414 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 3.2 |
| Rated power (kW) | 3.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 5.2 |
| Rated power (kW) | 5.2 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 6.5 |
| Rated power (kW) | 6.5 |
| AC input voltage (V) | 230 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 12 |
| Phase | Single phase |
| Rated power (kVA) | 1.2 |
| Rated power (kW) | 1.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 330 x 104 x 414 |
| Floating charge voltage (V) | 13.5 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 70 |
| Max charge current (A) | 90 |
| Max efficiency (%) | 90 |
| Max PV input current (A) | 13 |
| Max PV input power (kW) | 2 |
| Max PV voltage (V) | 350 |
| Max solar charge current (A) | 90 |
| MPPT voltage range (V) | 30-300 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 16 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 2.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 9 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 2.5 |
| Rated power (kW) | 2.5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 90 |
| Max charge current (A) | 110 |
| Max efficiency (%) | 90 |
| Max PV input current (A) | 13 |
| Max PV input power (kW) | 3 |
| Max PV voltage (V) | 450 |
| Max solar charge current (A) | 110 |
| MPPT voltage range (V) | 30-400 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 31 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 5 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 8.7 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 3.2 |
| Rated power (kW) | 3.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 120 x 490 |
| Floating charge voltage (V) | 27 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 90 |
| Max charge current (A) | 110 |
| Max efficiency (%) | 90 |
| Max PV input current (A) | 18 |
| Max PV input power (kW) | 4 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 110 |
| MPPT voltage range (V) | 30-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 31 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 6.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 11.6 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 5.2 |
| Rated power (kW) | 5.2 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 90 |
| Max charge current (A) | 90 |
| Max efficiency (%) | 91 |
| Max PV input current (A) | 18 |
| Max PV input power (kW) | 5.5 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 90 |
| MPPT voltage range (V) | 90-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 63 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 10.4 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 13 |
| Battery class | Low voltage |
|---|---|
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 6.5 |
| Rated power (kW) | 6.5 |
| AC input voltage (V) | 230 |
| AC voltage regulation batt mode | 5 |
| Communication interface | RS232/RS485(BMS)/WIFI |
| Dimension (mm) | 372 x 142 x 590 |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Max AC charge current (A) | 100 |
| Max charge current (A) | 120 |
| Max efficiency (%) | 91 |
| Max PV input current (A) | 22 |
| Max PV input power (kW) | 8 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 120 |
| MPPT voltage range (V) | 90-450 |
| Operating temperature (°C) | -10 to 50 |
| Overcharge protection (V) | 66 |
| Relative humidity (%) | 5-95 |
| Safety standard | CE, IEC 62116, IEC 61727 |
| Solar charger type | MPPT |
| Storage temperature (°C) | -15 to 60 |
| Surge power (kVA) | 13 |
| Transfer time (ms) | 10-20 |
| Waveform | Pure sine wave |
| Weight (kg) | 14.5 |
ATOM
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity0.6 kVA
Price—
Details
ATOM LOBO
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING II
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING II TWIN
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
AXPERT KING II TWIN 5G HELIUS
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity6.2 kW
Price$478
Details