FR
  1. Accueil
  2. Produits
  3. Felicity
  4. Onduleur
  5. Hybride
  6. IVGM
Felicity IVGM Inverter hybrid low voltage single phase IVGM
Felicity

Felicity IVGM Inverter hybrid low voltage single phase 16 kW

The largest single-phase hybrid Felicity builds at 16 kW, on a low-voltage battery bank and taking up to 25.6 kW of panels. Where a site needs more than this, the next step is three-phase.

TypeOnduleurRéseauHybridePhaseMonophaséBatterieBasse tension
Capacité
Prix—

Caractéristiques clés

AC output voltage (V)220/230
Battery classLow voltage
Grid typeHybrid
PhaseSingle phase
Rated power (kVA)16
Rated power (kW)16
AC grid connection typeL+N+PE
AC input voltage (V)220-230
Toutes les caractéristiques65
AC output voltage (V)220/230
Battery classLow voltage
Grid typeHybrid
PhaseSingle phase
Rated power (kVA)16
Rated power (kW)16
AC grid connection typeL+N+PE
AC input voltage (V)220-230
AC short circuit protectionYes
Battery typeLead-acid, Lithium-ion
Battery voltage range (V)40-60
BMS communicationRS485, CAN
Charge algorithmSelf-adaption to BMS
Communication interfaceRS485, RS232, CAN
CoolingAir Cooling
DC switchYes
Dimension (mm)760 x 285 x 450
DisplayLCD
Grid frequency (Hz)50/60
Grid frequency range 50 (Hz)45-55
Grid frequency range 60 (Hz)55-65
Grid regulationIEC 61727, IEC 62116, NRS 097 (in progress)
Ground fault monitoringYes
Input voltage range (V)195.5-253
IP ratingIP65
Max AC input current (A)80
Max AC passthrough (A)100
Max apparent power (kVA)17.6
Max charge current (A)290
Max discharge current (A)290
Max efficiency (%)97.6
Max output current (A)76.5
Max PV access power (kW)32
Max PV input current (A)26+26+26
Max PV input power (kW)25.6
Max PV voltage (V)500
Max short circuit current (A)44+44+44
Monitor moduleWiFi/Bluetooth
MPPT count3
MPPT voltage range (V)150-425
Number of battery inputs2
Operating temperature (°C)-25 to 60 (>45 derating)
Output frequency (Hz)50/60
Overload protectionYes
Overvoltage category ACIII
Overvoltage category DCII
Package dimension (mm)895 x 419 x 570
Package weight (kg)63.6
Parallel units6
Power factor adjustable range0.8 leading to 0.8 lagging
ProtectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Rated AC output current (A)69.6
Rated PV input voltage (V)370
Safety standardIEC/EN 62109-1, IEC/EN 62109-2
Startup voltage (V)125
Strings per MPPT2+2+2
Surge duration (s)10
Surge power multiple2
Surge protection level ACII
Surge protection level DCII
THD (%)3
TopologyNon-Isolated
Transfer time (ms)10
Warranty (years)10
Weight (kg)53

Voir aussi

Felicity AI100 48V inverter single phase AI100 48V TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension Capacité Prix— Détails
Felicity IVAM 48V inverter off-grid single phase IVAM 48V TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension Capacité Prix— Détails
Felicity IVBM 48V inverter off-grid single phase IVBM 48V TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension Capacité Prix— Détails
Felicity IVCM 12V inverter off-grid single phase IVCM 12V TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension Capacité2 kW Prix— Détails
Felicity IVCM 24V inverter off-grid single phase IVCM 24V TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension Capacité3.2 kW Prix— Détails
Felicity IVDM 24V inverter off-grid single phase IVDM 24V TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension Capacité4.2 kW Prix— Détails