AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVGM
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 7.6 |
| Rated power (kW) | 7.6 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 654 x 243 x 430 |
| Display | LCD, LED |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | CEI 0-21, G99, VDE 4105, EN 50549-1, NRS 097-2-1, C10/11, NTS & UNE217001 & UNE217002, PORTARIA N° 140 & 515 |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC input current (A) | 40 |
| Max AC output power (kW) | 5.5 |
| Max AC passthrough (A) | 40 |
| Max altitude (m) | 2000 |
| Max charge current (A) | 120 |
| Max charge power (kW) | 5 |
| Max discharge current (A) | 120 |
| Max discharge power (kW) | 5 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 22.9 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 7.5 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 17+17 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 290-425 |
| MPPT voltage range (V) | 120-425 |
| Noise (dB) | 35 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Power factor | 0.99 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| PV voltage working range (V) | 90-500 |
| Rated AC output current (A) | 20.8 |
| Rated PV input voltage (V) | 380 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Strings per MPPT | 1+1 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 6 |
| Rated power (kW) | 6 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 654 x 243 x 430 |
| Display | LCD, LED |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC input current (A) | 40 |
| Max AC output power (kW) | 6.6 |
| Max AC passthrough (A) | 40 |
| Max altitude (m) | 2000 |
| Max charge current (A) | 135 |
| Max charge power (kW) | 6 |
| Max discharge current (A) | 135 |
| Max discharge power (kW) | 6 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 27.5 |
| Max PV input current (A) | 26+13 |
| Max PV input power (kW) | 9 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+17 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 230-425 |
| MPPT voltage range (V) | 120-425 |
| Noise (dB) | 35 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Power factor | 0.99 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| PV voltage working range (V) | 90-500 |
| Rated AC output current (A) | 25 |
| Rated PV input voltage (V) | 380 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Strings per MPPT | 2+1 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 7.6 |
| Rated power (kW) | 7.6 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 654 x 243 x 430 |
| Display | LCD, LED |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 8.36 |
| Max AC passthrough (A) | 50 |
| Max altitude (m) | 2000 |
| Max charge current (A) | 190 |
| Max charge power (kW) | 7.6 |
| Max discharge current (A) | 190 |
| Max discharge power (kW) | 7.6 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 34.8 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 11.4 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+44 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 230-425 |
| MPPT voltage range (V) | 120-425 |
| Noise (dB) | 35 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Power factor | 0.99 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| PV voltage working range (V) | 90-500 |
| Rated AC output current (A) | 31.7 |
| Rated PV input voltage (V) | 380 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
| AC output voltage (V) | 120/240 |
|---|---|
| Battery class | Low voltage |
| Grid type | Hybrid |
| Phase | Split phase 120/240 |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L1+L2+N+PE |
| AC input voltage (V) | 220-230 |
| AC short circuit protection | Yes |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 40-60 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 654 x 243 x 430 |
| Display | LCD, LED |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | VDE 4105, CEI 0-21, G99, NRS 097-2-1, EN 50549-1, EN 50549-10, NC RFG (Poland), EN 50549-1/-10+Netherlands, PPDS, NTS & UNE217001 & UNE217002, UL1741 (in progress) |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 8.8 |
| Max AC passthrough (A) | 50 |
| Max altitude (m) | 2000 |
| Max charge current (A) | 190 |
| Max charge power (kW) | 8 |
| Max discharge current (A) | 190 |
| Max discharge power (kW) | 8 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 36.7 |
| Max PV input current (A) | 26+26 |
| Max PV input power (kW) | 12 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 44+44 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 230-425 |
| MPPT voltage range (V) | 120-425 |
| Noise (dB) | 35 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Package dimension (mm) | 787 x 358 x 547 |
| Package weight (kg) | 40.5 |
| Parallel units | 6 |
| Power factor | 0.99 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Short-Circuit Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| PV voltage working range (V) | 90-500 |
| Rated AC output current (A) | 33.3 |
| Rated PV input voltage (V) | 380 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 100 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| THD (%) | 3 |
| Topology | Isolated (transformer-based) |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 33.5 |
AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVAM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVBM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVCM 12V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité2 kW
Prix—
Détails
IVCM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité3.2 kW
Prix—
Détails
IVDM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité4.2 kW
Prix—