AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
T-REX
25 kW three-phase hybrid with two solar trackers, for a small commercial building.
| AC output voltage (V) | 230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 25 |
| Rated power (kW) | 25 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 29.9 |
| Rated power (kW) | 29.9 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 30 |
| Rated power (kW) | 30 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 40 |
| Rated power (kW) | 40 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 50 |
| Rated power (kW) | 50 |
| AC grid connection type | 3L+N+PE/3L+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 230 |
| AC output line voltage (V) | 400 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 30 |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 180-580 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| Dimension (mm) | 533 x 213 x 431 |
| Display | LCD, LED |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | VDE-AR-N 4105, G99/1, EN50549-1, CEI 0-21, AS 4777.2, NRS 097-2-1 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC charge current (A) | 25 |
| Max AC input current (A) | 30 |
| Max AC output power (kW) | 10 |
| Max AC passthrough (A) | 30 |
| Max altitude (m) | 2000 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 10 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 10 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 18 |
| Max PV input current (A) | 15+15 |
| Max PV input power (kW) | 13 |
| Max PV voltage (V) | 900 |
| Max short circuit current (A) | 18+18 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 450-850 |
| MPPT voltage range (V) | 200-850 |
| Nominal AC input line voltage (V) | 400 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -25 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 635 x 315 x 533 |
| Package weight (kg) | 39.7 |
| Parallel units | 10 |
| Power factor | 0.99 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | Output Over Current Protection, Output Over Power Protection, Output Shorted Protection, Anti-islanding Protection, GFCI Protection, Insulation Resistor Detection |
| PV voltage working range (V) | 160-900 |
| Rated AC output current (A) | 14.5 |
| Rated PV input voltage (V) | 720 |
| Relative humidity (%) | 0-100 |
| Safety standard | IEC 62109-1, IEC 62109-2, IEC 62040-1 |
| Startup voltage (V) | 160 |
| Strings per MPPT | 1 |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 20 |
| Warranty (years) | 10 |
| Weight (kg) | 35.3 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 25 |
| Rated power (kW) | 25 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, NC RFG (Poland), VDE 4105, G99, EN 50549-1, EN 50549-1+Netherlands |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC output power (kW) | 27.5 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 39.9 |
| Max output overcurrent protection (A) | 144 |
| Max PV input current (A) | 36+36 |
| Max PV input power (kW) | 32.5 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 450-850 |
| MPPT voltage range (V) | 200-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 102.3 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 36.3 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 250 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 85.6 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 29.9 |
| Rated power (kW) | 29.9 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, NC RFG (Poland), VDE 4105, G99, EN 50549-1, EN 50549-1+Netherlands |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC output power (kW) | 29.9 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 43.4 |
| Max output overcurrent protection (A) | 144 |
| Max PV input current (A) | 36+36+36 |
| Max PV input power (kW) | 38.87 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 3 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 360-850 |
| MPPT voltage range (V) | 200-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 102.3 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 43.4 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 250 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 85.6 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 30 |
| Rated power (kW) | 30 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, NC RFG (Poland), VDE 4105, G99, EN 50549-1, EN 50549-1+Netherlands |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC output power (kW) | 33 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 47.9 |
| Max output overcurrent protection (A) | 144 |
| Max PV input current (A) | 36+36+36 |
| Max PV input power (kW) | 39 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 3 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 360-850 |
| MPPT voltage range (V) | 200-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 102.3 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 43.5 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 250 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 85.6 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 40 |
| Rated power (kW) | 40 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, NC RFG (Poland), VDE 4105, G99, EN 50549-1, EN 50549-1+Netherlands |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC output power (kW) | 44 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 63.8 |
| Max output overcurrent protection (A) | 192 |
| Max PV input current (A) | 36+36+36+36 |
| Max PV input power (kW) | 52 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 4 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 360-850 |
| MPPT voltage range (V) | 200-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 102.3 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 58 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 250 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 85.6 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 50 |
| Rated power (kW) | 50 |
| AC grid connection type | 3L+N+PE/3L+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP65 |
| Max AC output power (kW) | 55 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 79.7 |
| Max PV input current (A) | 36+36+36+36 |
| Max PV input power (kW) | 65 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 4 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 450-850 |
| MPPT voltage range (V) | 200-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -25 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1110 x 463 x 770 |
| Package weight (kg) | 98.4 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Integrated Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Output Over Voltage Protection, Anti-islanding Protection, AC Output Lightning Protection |
| Rated AC output current (A) | 72.5 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 250 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 85.6 |
AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVAM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVBM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVCM 12V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité2 kW
Prix—
Détails
IVCM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité3.2 kW
Prix—
Détails
IVDM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité4.2 kW
Prix—
Détails