AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVDM 24V
4.2 kW off-grid, enough for a small home's lighting, refrigeration, fans and entertainment on a 24 V bank.
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 4.2 |
| Rated power (kW) | 4.2 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 24 |
| Phase | Single phase |
| Rated power (kVA) | 4.2 |
| Rated power (kW) | 4.2 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 20 |
| Battery type | Lead-acid, Lithium-ion |
| Battery voltage range (V) | 20-30 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, CAN |
| Cooling | Air Cooling |
| Dimension (mm) | 403 x 137 x 313 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Ground fault monitoring | No |
| IP rating | IP6X |
| Max AC input current (A) | 25 |
| Max AC output power (kW) | 4.26 |
| Max AC passthrough (A) | 25 |
| Max apparent power (kVA) | 4.26 |
| Max charge current (A) | 160 |
| Max discharge current (A) | 160 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 20 |
| Max PV access power (kW) | 10 |
| Max PV input current (A) | 20 |
| Max PV input power (kW) | 8 |
| Max PV voltage (V) | 500 |
| Max short circuit current (A) | 27 |
| Monitor module | WiFi/LAN (optional) |
| MPPT count | 1 |
| MPPT full load voltage range (V) | 300-425 |
| MPPT voltage range (V) | 60-425 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 495 x 227 x 405 |
| Package weight (kg) | 10.3 |
| Parallel units | 6 |
| Protection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, Overvoltage Load Drop Protection, DC Component Monitoring |
| PV voltage working range (V) | 60-500 |
| Rated PV input voltage (V) | 370 |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 60 |
| Strings per MPPT | 1 |
| Surge duration (s) | 10 |
| Surge power multiple | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Warranty (years) | 5 |
| Waveform | Pure sine wave |
| Weight (kg) | 8.3 |
AI100 48V
TypeOnduleurRéseauStockagePhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVAM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVBM 48V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité
Prix—
Détails
IVCM 12V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité2 kW
Prix—
Détails
IVCM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité3.2 kW
Prix—
Détails
IVEM 24V
TypeOnduleurRéseauHors réseauPhaseMonophaséBatterieBasse tension
Capacité3 kW
Prix—
Détails