G01P3
النوعانفرترالشبكةمتصل بالشبكةالأطوارثلاثة أطوار
القدرة
السعر$3,400
التفاصيل
G06P3
An 8 kW three-phase on-grid inverter for a small commercial rooftop; no battery port.
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 3 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 4 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 5 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 6 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 7 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 8 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 9 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 10 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 12 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 15 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 3 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.5 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 3.3 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 3.3 |
| Max efficiency (%) | 98.1 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 5/4.8 |
| Max output fault current (A) | 8.8 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 4.5 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 350-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 4.6/4.4 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 4 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.5 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 4.4 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 4.4 |
| Max efficiency (%) | 98.1 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 6.7/6.4 |
| Max output fault current (A) | 11.6 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 6 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 350-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 6.1/5.8 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 5 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.6 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 5.5 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 5.5 |
| Max efficiency (%) | 98.2 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 8.4/8 |
| Max output fault current (A) | 14.6 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 7.5 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 350-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 7.6/7.3 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 6 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.6 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 6.6 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 6.6 |
| Max efficiency (%) | 98.2 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 10/9.6 |
| Max output fault current (A) | 30.2 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 9 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 350-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 9.1/8.7 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 7 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.8 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 7.7 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 7.7 |
| Max efficiency (%) | 98.3 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 11.7/11.2 |
| Max output fault current (A) | 20.4 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 10.5 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 480-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 10.7/10.2 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 8 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.8 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 8.8 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 8.8 |
| Max efficiency (%) | 98.3 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 13.4/12.8 |
| Max output fault current (A) | 23.2 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 12 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 480-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 12.2/11.6 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 9 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.8 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 9.9 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 9.9 |
| Max efficiency (%) | 98.3 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 15/14.4 |
| Max output fault current (A) | 26.2 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 13.5 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 480-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 13.7/13.1 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 10 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.8 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 11 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 11 |
| Max efficiency (%) | 98.3 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 16.7/16 |
| Max output fault current (A) | 33.4 |
| Max output overcurrent protection (A) | 70 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 15 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 480-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 15.2/14.5 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 12 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 178 x 525 |
| European efficiency (%) | 97.8 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 13.2 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 13.2 |
| Max efficiency (%) | 98.3 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 20/19.2 |
| Max output fault current (A) | 40 |
| Max output overcurrent protection (A) | 70 |
| Max PV input current (A) | 13+13 |
| Max PV input power (kW) | 18 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+19.5 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 480-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 18.2/17.4 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+1 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 11.5 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 15 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232 |
| Cooling | Nature |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Derating start temp (°C) | 45 |
| Dimension (mm) | 283 x 188 x 525 |
| European efficiency (%) | 98.0 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid monitoring | Yes |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105 |
| Ground fault monitoring | Yes |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 16.5 |
| Max efficiency (%) | 98.5 |
| Max output current (A) | 25/24 |
| Max output fault current (A) | 43.6 |
| Max output overcurrent protection (A) | 47.7 |
| Max PV input current (A) | 13/26 |
| Max PV input power (kW) | 22.5 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 19.5+39 |
| Monitor module | GPRS, Wi-Fi, Bluetooth, 4G, LAN (optional) |
| MPPT count | 2 |
| MPPT efficiency (%) | 99 |
| MPPT full load voltage range (V) | 480-850 |
| MPPT voltage range (V) | 120-1000 |
| Noise (dB) | 45 |
| Operating temperature (°C) | -25 to 60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 22.8/21.8 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 140 |
| String monitoring | Optional |
| Strings per MPPT | 1+2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 12 |
| Zero export support | Yes |
G01P3
النوعانفرترالشبكةمتصل بالشبكةالأطوارثلاثة أطوار
القدرة
السعر$3,400
التفاصيل
G02P1
النوعانفرترالشبكةمتصل بالشبكةالأطوارطور واحد
القدرة
السعر—
التفاصيل
G03
النوعانفرترالشبكةمتصل بالشبكةالأطوارثلاثة أطوار
القدرة
السعر$2,880
التفاصيل
G04
النوعانفرترالشبكةمتصل بالشبكةالأطوارثلاثة أطوار
القدرة
السعر—
التفاصيل
G04
النوعانفرترالشبكةمتصل بالشبكةالأطوارطور واحد
القدرة
السعر—
التفاصيل
G04P1
النوعانفرترالشبكةمتصل بالشبكةالأطوارطور واحد
القدرة
السعر—
التفاصيل