AI100 48V
النوعانفرترالشبكةتخزينالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVGM
29.9 kW three-phase hybrid with three trackers — the size that sits just under a 30 kW connection limit.
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 25 |
| Rated power (kW) | 25 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 29.9 |
| Rated power (kW) | 29.9 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 30 |
| Rated power (kW) | 30 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 40 |
| Rated power (kW) | 40 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 50 |
| Rated power (kW) | 50 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 75 |
| Rated power (kW) | 75 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 80 |
| Rated power (kW) | 80 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 100 |
| Rated power (kW) | 100 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 125 |
| Rated power (kW) | 125 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 25 |
| Rated power (kW) | 25 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output line voltage (V) | 190-480 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 27.5 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 39.9 |
| Max output overcurrent protection (A) | 144 |
| Max PV access power (kW) | 50 |
| Max PV input current (A) | 36+36 |
| Max PV input power (kW) | 40 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 2 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 555-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 190-480 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 107.1 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 36.3 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 87.1 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 29.9 |
| Rated power (kW) | 29.9 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output line voltage (V) | 190-480 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 29.9 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 43.4 |
| Max output overcurrent protection (A) | 144 |
| Max PV access power (kW) | 59.8 |
| Max PV input current (A) | 36+36+36 |
| Max PV input power (kW) | 47.84 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 3 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 443-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 190-480 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 107.1 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 43.4 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 87.1 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 30 |
| Rated power (kW) | 30 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output line voltage (V) | 190-480 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 33 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 47.9 |
| Max output overcurrent protection (A) | 144 |
| Max PV access power (kW) | 60 |
| Max PV input current (A) | 36+36+36 |
| Max PV input power (kW) | 48 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 3 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 444-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 190-480 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 107.1 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 43.5 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 87.1 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 40 |
| Rated power (kW) | 40 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output line voltage (V) | 190-480 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 44 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 63.8 |
| Max output overcurrent protection (A) | 192 |
| Max PV access power (kW) | 80 |
| Max PV input current (A) | 36+36+36+36 |
| Max PV input power (kW) | 64 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 4 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 444-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 190-480 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 107.1 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 58 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 87.1 |
| AC output voltage (V) | 110-277 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 50 |
| Rated power (kW) | 50 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 110-277 |
| AC output line voltage (V) | 190-480 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-800 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 940 x 340 x 582 |
| Display | LCD |
| European efficiency (%) | 97 |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | NTS & UNE217001 & UNE217002, CEI 0-21, NRS 097-2-1, EN50549-1/-10+Poland Deviations, VDE 4105, G99, EN50549-1/-10, EN50549-1/-10+Netherlands Deviations |
| Ground fault monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 55 |
| Max AC passthrough (A) | 200 |
| Max altitude (m) | 3000 (>2000 derating) |
| Max charge current (A) | 50+50 |
| Max discharge current (A) | 50+50 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 79.7 |
| Max PV access power (kW) | 100 |
| Max PV input current (A) | 36+36+36+36 |
| Max PV input power (kW) | 80 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 55+55+55+55 |
| Min DC input voltage (V) | 150 |
| Monitor module | WiFi/GPRS |
| MPPT count | 4 |
| MPPT efficiency (%) | 99.9 |
| MPPT full load voltage range (V) | 550-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 190-480 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>50 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1114 x 469 x 774 |
| Package weight (kg) | 107.1 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, AC Output Lightning Protection, Battery Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Short-Circuit Protection, Output Over Voltage Protection, Anti-islanding Protection |
| Rated AC output current (A) | 72.5 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-95 (non-condensing) |
| Safety standard | EN 62477-1, IEC 62109-1, IEC 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 10 |
| Warranty (years) | 10 |
| Weight (kg) | 87.1 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 75 |
| Rated power (kW) | 75 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-1000 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 1271 x 379.5 x 814.5 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4110 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP66 |
| Max AC input current (A) | 119.6 |
| Max AC passthrough (A) | 270 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 82.5 |
| Max charge current (A) | 120+120 |
| Max discharge current (A) | 120+120 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 119.6 |
| Max output overcurrent protection (A) | 218 |
| Max PV input current (A) | 45+45+45+45+45+45+45+45 |
| Max PV input power (kW) | 150 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 68+68+68+68+68+68+68+68 |
| Monitor module | WiFi/Bluetooth/4G/LAN |
| MPPT count | 8 |
| MPPT full load voltage range (V) | 416-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1410 x 646 x 960 |
| Package weight (kg) | 200 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, Battery Input Reverse Polarity Protection, DC Component Detection, Insulation Resistor Detection, Residual Current Monitoring Unit, Arc Fault Monitoring (optional), Output Over Current Protection, Output Shorted Protection, Output Over Voltage Protection, Remaining Current (RCD) Monitoring, Overheat Protection, Anti-islanding Protection, AC Output Lightning Protection |
| Rated AC output current (A) | 108.7 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 (non-condensing) |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | III |
| Surge protection level DC | III |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 0 |
| Warranty (years) | 10 |
| Weight (kg) | 156 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 80 |
| Rated power (kW) | 80 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-1000 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 1271 x 379.5 x 814.5 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4110 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP66 |
| Max AC input current (A) | 127.5 |
| Max AC passthrough (A) | 270 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 88 |
| Max charge current (A) | 120+120 |
| Max discharge current (A) | 120+120 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 127.5 |
| Max output overcurrent protection (A) | 218 |
| Max PV input current (A) | 45+45+45+45+45+45+45+45 |
| Max PV input power (kW) | 160 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 68+68+68+68+68+68+68+68 |
| Monitor module | WiFi/Bluetooth/4G/LAN |
| MPPT count | 8 |
| MPPT full load voltage range (V) | 444-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1410 x 646 x 960 |
| Package weight (kg) | 200 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, Battery Input Reverse Polarity Protection, DC Component Detection, Insulation Resistor Detection, Residual Current Monitoring Unit, Arc Fault Monitoring (optional), Output Over Current Protection, Output Shorted Protection, Output Over Voltage Protection, Remaining Current (RCD) Monitoring, Overheat Protection, Anti-islanding Protection, AC Output Lightning Protection |
| Rated AC output current (A) | 116 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 (non-condensing) |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | III |
| Surge protection level DC | III |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 0 |
| Warranty (years) | 10 |
| Weight (kg) | 156 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 100 |
| Rated power (kW) | 100 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-1000 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 1271 x 379.5 x 814.5 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4110 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP66 |
| Max AC input current (A) | 159.4 |
| Max AC passthrough (A) | 270 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 110 |
| Max charge current (A) | 120+120 |
| Max discharge current (A) | 120+120 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 159.4 |
| Max output overcurrent protection (A) | 270 |
| Max PV input current (A) | 45+45+45+45+45+45+45+45 |
| Max PV input power (kW) | 200 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 68+68+68+68+68+68+68+68 |
| Monitor module | WiFi/Bluetooth/4G/LAN |
| MPPT count | 8 |
| MPPT full load voltage range (V) | 444-850 |
| MPPT voltage range (V) | 150-850 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1410 x 646 x 960 |
| Package weight (kg) | 200 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, Battery Input Reverse Polarity Protection, DC Component Detection, Insulation Resistor Detection, Residual Current Monitoring Unit, Arc Fault Monitoring (optional), Output Over Current Protection, Output Shorted Protection, Output Over Voltage Protection, Remaining Current (RCD) Monitoring, Overheat Protection, Anti-islanding Protection, AC Output Lightning Protection |
| Rated AC output current (A) | 145 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 (non-condensing) |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | III |
| Surge protection level DC | III |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 0 |
| Warranty (years) | 10 |
| Weight (kg) | 156 |
| AC output voltage (V) | 220/230 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kVA) | 125 |
| Rated power (kW) | 125 |
| AC grid connection type | 3L+N+PE |
| AC input voltage (V) | 220-230 |
| AC output line voltage (V) | 380-400 |
| AC short circuit protection | Yes |
| Battery type | LiFePO4 |
| Battery voltage range (V) | 160-950 |
| BMS communication | RS485, CAN |
| Charge algorithm | Self-adaption to BMS |
| Communication interface | RS485, RS232 |
| Cooling | Air Cooling |
| Dimension (mm) | 1271 x 364 x 810 |
| Display | LCD, LED |
| Grid frequency (Hz) | 50/60 |
| Grid frequency range 50 (Hz) | 45-55 |
| Grid frequency range 60 (Hz) | 55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4110 |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 184-264.5 |
| IP rating | IP66 |
| Max AC input current (A) | 198.6 |
| Max AC passthrough (A) | 270 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 137 |
| Max charge current (A) | 120+120 |
| Max discharge current (A) | 120+120 |
| Max efficiency (%) | 97.6 |
| Max output current (A) | 198.6 |
| Max output overcurrent protection (A) | 270 |
| Max PV input current (A) | 45+45+45+45+45+45+45+45+45+45 |
| Max PV input power (kW) | 250 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 68+68+68+68+68+68+68+68+68+68 |
| Monitor module | WiFi/Bluetooth/4G/LAN (optional) |
| MPPT count | 10 |
| MPPT full load voltage range (V) | 555-950 |
| MPPT voltage range (V) | 150-950 |
| Nominal AC input line voltage (V) | 380-400 |
| Number of battery inputs | 2 |
| Operating temperature (°C) | -40 to 60 (>45 derating) |
| Output frequency (Hz) | 50/60 |
| Overload protection | Yes |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Package dimension (mm) | 1410 x 646 x 960 |
| Package weight (kg) | 198 |
| Parallel units | 12 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Protection | PV Input Lightning Protection, PV String Input Reverse Polarity Protection, Battery Input Lightning Protection, Battery Input Reverse Polarity Protection, DC Component Detection, Insulation Resistor Detection, Residual Current Monitoring Unit, Arc Fault Monitoring (optional), Output Over Current Protection, Output Shorted Protection, Output Over Voltage Protection, Remaining Current (RCD) Monitoring, Overheat Protection, Anti-islanding Protection, AC Output Lightning Protection |
| Rated AC output current (A) | 181.2 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 (non-condensing) |
| Safety standard | IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 180 |
| Strings per MPPT | 2 |
| Surge duration (s) | 10 |
| Surge power multiple | 1.5 |
| Surge protection level AC | III |
| Surge protection level DC | III |
| THD (%) | 3 |
| Topology | Non-Isolated |
| Transfer time (ms) | 0 |
| Warranty (years) | 10 |
| Weight (kg) | 155.5 |
AI100 48V
النوعانفرترالشبكةتخزينالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVAM 48V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر—
التفاصيل
IVBM 48V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة
السعر$810
التفاصيل
IVCM 12V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة2 kW
السعر—
التفاصيل
IVCM 24V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة3.2 kW
السعر—
التفاصيل
IVDM 24V
النوعانفرترالشبكةمستقلالأطوارطور واحدالبطاريةجهد منخفض
القدرة4.2 kW
السعر—
التفاصيل