Deye SG02HP3 Hybrid inverter 70 kW

Deye SG02HP3 Hybrid inverter 70 kW

TypeInverterGridHybridPhaseThree phaseBatteryHigh voltage Capacity30 kW60 kW70 kW75 kW80 kW
Price—

Coming in 4 weeks

Description

A 70 kW three-phase hybrid with six trackers, for a factory or large commercial array on a high-voltage battery.

Key specifications

AC output voltage (V)220/380, 230/400
Battery typeLithium-ion
IP ratingIP65
Max charge current (A)80+80
Max efficiency (%)98.7
Max PV input power (kW)112
Max PV voltage (V)1000
MPPT count6
All specifications75

AC

AC output voltage (V)220/380, 230/400
Grid typeHybrid
PhaseThree phase
AC couple supportYes
AC grid connection type3L+N+PE
AC voltage tolerance un0.85-1.1
Grid frequency (Hz)50/45-55, 60/55-65
Grid regulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Max AC passthrough (A)200
Max apparent power (kVA)77
Max output current (A)116.7/111.6
Power factor adjustable range0.8 leading to 0.8 lagging
Rated AC output current (A)106.1/101.5
THD (%)3
Unbalanced output (%)100

PV and DC

DC component monitoringYes
DC injection current pct of in0.5
DC reverse polarity protectionYes
DC switchYes
Max PV access power (kW)140
Max PV input current (A)36+36+36+36+36+36
Max PV input power (kW)112
Max PV voltage (V)1000
Monitor moduleGPRS, Wi-Fi, Bluetooth, 4G, LAN (optional)
MPPT count6
MPPT efficiency (%)99
MPPT voltage range (V)150-850
Overvoltage category DCII
Rated PV input voltage (V)650
Strings per MPPT2+2+2+2+2+2
Surge protection level DCII

Battery

Battery classHigh voltage
Battery parallel supportYes
Battery typeLithium-ion
Battery voltage range (V)160-1000
Charge algorithmSelf-adaption to BMS
Charge discharge time periods6
Max charge current (A)80+80
Max discharge current (A)80+80
Number of battery inputs2
Approved battery familiesDeye, Dyness, UZ, Shoto, Pylontech, BYD

Protection

AC output overcurrent protectionYes
AC output overvoltage protectionYes
AC short circuit protectionYes
AFCI protectionOptional
Anti islanding protectionYes
Insulation resistance monitoringYes
IP ratingIP65
Max short circuit current (A)54+54+54+54+54+54
Overvoltage category ACIII
Surge duration (s)10
Surge power multiple1.5
Surge protection level ACII
Thermal protectionYes

Communication

Communication interfaceRS485, RS232, CAN
DisplayLCD, LED
Residual current monitoringYes

General

Rated power (kW)70
CoolingAir Cooling
Derating start temp (°C)45
Dimension (mm)606 x 314 x 927
European efficiency (%)98.1
Generator supportYes (Diesel)
Max altitude (m)3000
Max efficiency (%)98.7
Max inverter backfeed current (A)0
Noise (dB)65
Operating temperature (°C)-40 to 60
Parallel units10
Relative humidity (%)0-100
Safety standardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Startup voltage (V)180
TopologyNon-Isolated
Warranty (years)5
Weight (kg)105