G01P3
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price$3,400
Details
G03
An 80 kW six-tracker on-grid inverter for a large commercial or industrial roof.
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 70 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 75 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 80 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 90 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 100 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 110 |
| AC grid connection type | 3L+N+PE |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti PID | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 70 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232, WIFI, LAN |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 824 x 312.7 x 516 |
| Display | LCD |
| European efficiency (%) | 98.1 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 70 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 77 |
| Max efficiency (%) | 98.7 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 116.7/111.6 |
| Max PV input current (A) | 40+40+40+40 |
| Max PV input power (kW) | 91 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 60+60+60+60 |
| MPPT count | 4 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 200-850 |
| Noise (dB) | 55 |
| Operating temperature (°C) | -25 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 106.1/101.5 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 250 |
| String monitoring | Optional |
| Strings per MPPT | 4+4+4+4 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 81 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 75 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232, WIFI, LAN |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 824 x 312.7 x 516 |
| Display | LCD |
| European efficiency (%) | 98.1 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 75 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 82.5 |
| Max efficiency (%) | 98.7 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 125/119.6 |
| Max PV input current (A) | 40+40+40+40 |
| Max PV input power (kW) | 97.5 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 60+60+60+60 |
| MPPT count | 4 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 200-850 |
| Noise (dB) | 55 |
| Operating temperature (°C) | -25 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 113.6/108.7 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 250 |
| String monitoring | Optional |
| Strings per MPPT | 4+4+4+4 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 81 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 80 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232, WIFI, LAN |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 824 x 312.7 x 516 |
| Display | LCD |
| European efficiency (%) | 98.1 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 80 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 88 |
| Max efficiency (%) | 98.7 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 133.3/127.5 |
| Max PV input current (A) | 40+40+40+40 |
| Max PV input power (kW) | 104 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 60+60+60+60 |
| MPPT count | 4 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 200-850 |
| Noise (dB) | 55 |
| Operating temperature (°C) | -25 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 121.2/115.9 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 250 |
| String monitoring | Optional |
| Strings per MPPT | 4+4+4+4 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 81 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 90 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232, WIFI, LAN |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 824 x 312.7 x 516 |
| Display | LCD |
| European efficiency (%) | 98.2 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 90 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 99 |
| Max efficiency (%) | 98.8 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 150/143.5 |
| Max PV input current (A) | 40+40+40+40+40+40 |
| Max PV input power (kW) | 135 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 60+60+60+60+60+60 |
| MPPT count | 6 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 200-850 |
| Noise (dB) | 55 |
| Operating temperature (°C) | -25 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 136.4/130.4 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 250 |
| String monitoring | Optional |
| Strings per MPPT | 4+4+4+4+4+4 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 81 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 100 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232, WIFI, LAN |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 824 x 312.7 x 516 |
| Display | LCD |
| European efficiency (%) | 98.2 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 100 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 110 |
| Max efficiency (%) | 98.8 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 166.7/159.4 |
| Max PV input current (A) | 40+40+40+40+40+40 |
| Max PV input power (kW) | 150 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 60+60+60+60+60+60 |
| MPPT count | 6 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 200-850 |
| Noise (dB) | 55 |
| Operating temperature (°C) | -25 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 151.5/144.9 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 250 |
| String monitoring | Optional |
| Strings per MPPT | 4+4+4+4+4+4 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 81 |
| Zero export support | Yes |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Grid type | On-grid |
| Phase | Three phase |
| Rated power (kW) | 110 |
| AC grid connection type | 3L+N+PE |
| AC output overcurrent protection | Yes |
| AC output overvoltage protection | Yes |
| AC short circuit protection | Yes |
| AC voltage tolerance un | 0.85-1.1 |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Anti PID | Optional |
| Communication interface | RS485, RS232, WIFI, LAN |
| Cooling | Air Cooling |
| DC component monitoring | Yes |
| DC injection current pct of in | 0.5 |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 824 x 312.7 x 516 |
| Display | LCD |
| European efficiency (%) | 98.2 |
| Grid frequency (Hz) | 50/45-55, 60/55-65 |
| Grid regulation | IEC 61727, IEC 62116, CEI 0-21, CEI 0-16, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105, VDE-AR-N 4110 |
| Insulation resistance monitoring | Yes |
| IP rating | IP65 |
| Max AC output power (kW) | 110 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 121 |
| Max efficiency (%) | 98.8 |
| Max inverter backfeed current (A) | 0 |
| Max output current (A) | 183.3/175.4 |
| Max PV input current (A) | 40+40+40+40+40+40 |
| Max PV input power (kW) | 150 |
| Max PV voltage (V) | 1000 |
| Max short circuit current (A) | 60+60+60+60+60+60 |
| MPPT count | 6 |
| MPPT efficiency (%) | 99 |
| MPPT voltage range (V) | 200-850 |
| Noise (dB) | 55 |
| Operating temperature (°C) | -25 to 60 |
| Overvoltage category AC | III |
| Overvoltage category DC | II |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated AC output current (A) | 166.7/159.4 |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Safety standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
| Startup voltage (V) | 250 |
| String monitoring | Optional |
| Strings per MPPT | 4+4+4+4+4+4 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Thermal protection | Yes |
| Topology | Non-Isolated |
| Vsg support | Yes |
| Warranty (years) | 5 |
| Weight (kg) | 81 |
| Zero export support | Yes |
G01P3
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price$3,400
Details
G02P1
TypeInverterGridOn-gridPhaseSingle phase
Capacity
Price—
Details
G04
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
G04
TypeInverterGridOn-gridPhaseSingle phase
Capacity
Price—
Details
G04P1
TypeInverterGridOn-gridPhaseSingle phase
Capacity
Price—
Details
G04P3
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details