- Home
- Products
- Felicity
- Inverter
- Off-grid








Felicity IVEM 48V II Off-grid inverter 12 kW
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltageSystem48 V
Capacity6 kW8 kW12 kW
12 kW off-grid with a 240 A charge limit — the largest single-phase machine in the line, for heavy loads on one inverter.
| AC output voltage (V) | 230 |
|---|
| IP rating | IP21 |
|---|
| Max charge current (A) | 240 |
|---|
| Max efficiency (%) | 93 |
|---|
| Max PV input power (kW) | 15 |
|---|
| Max PV voltage (V) | 500 |
|---|
| MPPT count | 1 |
|---|
| MPPT voltage range (V) | 90-450 |
|---|
All specifications74
AC
| AC output voltage (V) | 230 |
|---|
| Grid type | Off-grid |
|---|
| Phase | Single phase |
|---|
| AC grid connection type | L+N+PE |
|---|
| AC input voltage (V) | 230 |
|---|
| Grid frequency (Hz) | 50/60 |
|---|
| High line frequency reconnect (Hz) | 63 |
|---|
| Max AC input voltage (V) | 280 |
|---|
| Max AC passthrough (A) | 63 |
|---|
| Output frequency (Hz) | 50/60 |
|---|
| Output voltage regulation (%) | 5 |
|---|
PV and DC
| High line disconnect (V) | 280 |
|---|
| High line frequency disconnect (Hz) | 65 |
|---|
| Low line disconnect apl (V) | 90 |
|---|
| Low line disconnect UPS (V) | 170 |
|---|
| Low line frequency disconnect (Hz) | 40 |
|---|
| Max PV input current (A) | 27+27 |
|---|
| Max PV input power (kW) | 15 |
|---|
| Max PV voltage (V) | 500 |
|---|
| Monitor module | Built-In WiFi |
|---|
| MPPT count | 1 |
|---|
| MPPT voltage range (V) | 90-450 |
|---|
| PV voltage working range (V) | 90-450 |
|---|
| Strings per MPPT | 2 |
|---|
Battery
| Battery class | Low voltage |
|---|
| Nominal battery voltage (V) | 48 |
|---|
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
|---|
| Battery voltage range (V) | 42-63 |
|---|
| BMS communication | RS485 |
|---|
| Bulk charging voltage (V) | 56.4 |
|---|
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
|---|
| Floating charge voltage (V) | 54 |
|---|
| Max AC charge current (A) | 240 |
|---|
| Max charge current (A) | 240 |
|---|
| Max solar charge current (A) | 240 |
|---|
| Number of battery inputs | 1 |
|---|
| Pass through without battery | Yes |
|---|
| Approved battery families | Felicity |
|---|
Protection
| AC short circuit protection | Yes |
|---|
| IP rating | IP21 |
|---|
| Overload protection | Yes |
|---|
| Overload trip time over 105pct load (s) | 10.5 |
|---|
| Overload trip time over 120pct load (s) | 7.5 |
|---|
| Overload trip time over 150pct load (s) | 5.5 |
|---|
| Overload trip time over 200pct load (s) | 0.2 |
|---|
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
|---|
| Surge duration (s) | 5 |
|---|
| Surge power multiple | 2 |
|---|
Communication
General
| Rated power (kVA) | 12 |
|---|
| Rated power (kW) | 12 |
|---|
| Cooling | Air Cooling |
|---|
| Dimension (mm) | 476 x 141 x 634 |
|---|
| High line reconnect (V) | 270 |
|---|
| Input voltage range apl (V) | 90-280 |
|---|
| Input voltage range UPS (V) | 170-280 |
|---|
| Input voltage range (V) | 90-280 |
|---|
| Low line reconnect apl (V) | 100 |
|---|
| Low line reconnect UPS (V) | 180 |
|---|
| Max efficiency (%) | 93 |
|---|
| Motor start capable | Yes |
|---|
| Operating temperature (°C) | -10 to 50 |
|---|
| Package dimension (mm) | 726 x 258 x 594 |
|---|
| Package weight (kg) | 28.7 |
|---|
| Package volume m3 | 0.117 |
|---|
| Hs code | 85044090 |
|---|
| Parallel units | 6 |
|---|
| Safety standard | IEC 62109-1, IEC 62109-2 |
|---|
| Startup voltage (V) | 100 |
|---|
| Storage temperature (°C) | -15 to 60 |
|---|
| Topology | High-Frequency |
|---|
| Transfer time (ms) | 50 |
|---|
| Waveform | Pure sine wave |
|---|
| Weight (kg) | 26.8 |
|---|