Felicity IVEM 48V inverter off-grid low voltage single phase IVEM 48V
Felicity

Felicity IVEM 48V inverter off-grid low voltage single phase 5 kW

5 kW off-grid on a 220/230 V supply with a 100 A charge limit — the most common household size in the line.

TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltageSystem48 V
Capacity
Price$710

Key specifications

AC output voltage (V)230
Battery classLow voltage
Grid typeOff-grid
PhaseSingle phase
Rated power (kVA)5
Rated power (kW)5
AC grid connection typeL+N+PE
AC input voltage (V)230
All specifications82
AC output voltage (V)230
Battery classLow voltage
Grid typeOff-grid
Nominal battery voltage (V)48
PhaseSingle phase
Rated power (kVA)5
Rated power (kW)5
AC grid connection typeL+N+PE
AC input voltage (V)230
AC short circuit protectionYes
Battery typeAGM, Flooded, Lithium-ion, Self-Defined
Battery voltage range (V)42-63
BMS communicationRS485
Bulk charging voltage (V)56.4
Charge algorithmThree-Stage: Boost CC, Boost CV, Float
CoolingAir Cooling
Dimension (mm)415 x 129 x 320
DisplayLCD
Floating charge voltage (V)54
Grid frequency (Hz)50/60
High DC input recovery (V)56.4
High line disconnect (V)280
High line frequency disconnect (Hz)65
High line frequency reconnect (Hz)63
High line reconnect (V)270
Input voltage range apl (V)90-280
Input voltage range UPS (V)170-280
Input voltage range (V)90-280
Input voltage waveformSinusoidal (utility or generator)
IP ratingIP21
Line mode efficiency (%)95
Low battery recovery load over 50pct (V)46
Low battery recovery load under 50pct (V)47
Low DC input shutdown load over 50pct (V)42
Low DC input shutdown load under 50pct (V)43
Low line disconnect apl (V)90
Low line disconnect UPS (V)170
Low line frequency disconnect (Hz)40
Low line frequency reconnect (Hz)42
Low line reconnect apl (V)100
Low line reconnect UPS (V)180
Max AC charge current (A)100
Max AC input voltage (V)280
Max AC passthrough (A)63
Max charge current (A)100
Max charging voltage (V)60
Max efficiency (%)93
Max PV input current (A)20
Max PV input power (kW)6
Max PV voltage (V)500
Max solar charge current (A)100
Monitor moduleBuilt-In WiFi
Motor start capableYes
MPPT count1
MPPT voltage range (V)120-500
Number of battery inputs1
Operating temperature (°C)0-55
Output frequency (Hz)50/60
Output voltage regulation (%)5
Overload protectionYes
Overload trip time over 105pct load (s)10.5
Overload trip time over 150pct load (s)5.5
Package dimension (mm)494 x 202 x 399
Package weight (kg)13.2
Parallel units12
Pass through without batteryYes
ProtectionOverload Protection, Over Temperature Protection, Short Circuit Protection
PV voltage working range (V)120-500
Safety standardIEC 62109-1, IEC 62109-2
Short circuit protection battery modeElectronic Circuit
Short circuit protection line modeCircuit Breaker
Startup voltage (V)125
Storage temperature (°C)-15 to 60
Strings per MPPT1
Surge duration (s)5
Surge power multiple2
TopologyHigh-Frequency
Transfer time apl (ms)20
Transfer time (ms)50
Transfer time UPS (ms)10
WaveformPure sine wave
Weight (kg)11.2

See also

Felicity AI100 48V inverter single phase AI100 48V TypeInverterGridStoragePhaseSingle phaseBatteryLow voltage Capacity Price— Details
Felicity IVAM 48V inverter off-grid single phase IVAM 48V TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage Capacity Price— Details
Felicity IVBM 48V inverter off-grid single phase IVBM 48V TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage Capacity Price$810 Details
Felicity IVCM 12V inverter off-grid single phase IVCM 12V TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage Capacity2 kW Price— Details
Felicity IVCM 24V inverter off-grid single phase IVCM 24V TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage Capacity3.2 kW Price— Details
Felicity IVDM 24V inverter off-grid single phase IVDM 24V TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage Capacity4.2 kW Price— Details