INFINITY
TypeInverterGridStoragePhaseSingle phase
Capacity0.3 kW
Price—
Details
MID TL3 XH
17 kW, where the roof is bigger than the daytime load and the surplus should be stored.
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 11 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 12 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 13 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 15 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 17 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 20 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 25 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 30 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AFCI protection | Optional |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 11 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 12.1 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 11 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 18.3 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 22 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 2 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 12 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 13.2 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 12 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 20 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 24 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 2 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 13 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 14.3 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 13 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 21.7 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 26 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 2 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 15 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 16.5 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 15 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 25 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 30 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 2 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 17 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 18.7 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 17 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 28.3 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 34 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 2 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 20 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 22 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 20 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 33.3 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 40 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 2 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 25 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 27.5 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 25 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 41.6 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 50 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 3 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
| AC output voltage (V) | 220/380, 230/400 |
|---|---|
| Battery class | High voltage |
| Grid type | Hybrid |
| Phase | Three phase |
| Rated power (kW) | 30 |
| AC connection type | Cable gland+OT terminal |
| AC grid connection type | 3W+N+PE |
| AC short circuit protection | Yes |
| AFCI protection | Optional |
| Anti islanding protection | Yes |
| Battery type | Lithium-ion |
| Battery voltage range (V) | 600-980 |
| Communication interface | RS485/USB/WIFI(opt)/GPRS(opt)/RF(opt)/LAN(opt) |
| Compatible battery models | APX HV Battery System |
| Cooling | Air Cooling |
| DC connector type | H4/MC4(Optional) |
| DC reverse polarity protection | Yes |
| DC switch | Yes |
| Dimension (mm) | 580 x 230 x 435 |
| Display | OLED, LED |
| European efficiency (%) | 98.5 |
| Grid frequency (Hz) | 50/60 |
| Grid monitoring | Yes |
| Ground fault monitoring | Yes |
| Input voltage range (V) | 340-440 |
| Insulation resistance monitoring | Yes |
| IP rating | IP66 |
| Max altitude (m) | 4000 |
| Max apparent power (kVA) | 30 |
| Max charge current (A) | 25 |
| Max charge power (kW) | 15-30 |
| Max discharge current (A) | 25 |
| Max discharge power (kW) | 30 |
| Max efficiency (%) | 98.75-98.80 |
| Max output current (A) | 45.5 |
| Max PV input current (A) | 32 |
| Max PV input power (kW) | 60 |
| Max PV voltage (V) | 1100 |
| Max short circuit current (A) | 40 |
| MPPT count | 3 |
| MPPT voltage range (V) | 160-1000 |
| Nighttime power (W) | 5.5 |
| Operating temperature (°C) | -25 to 60 |
| Power factor adjustable range | 0.8 leading to 0.8 lagging |
| Rated PV input voltage (V) | 600 |
| Relative humidity (%) | 0-100 |
| Residual current monitoring | Yes |
| Startup voltage (V) | 200 |
| String monitoring | Yes |
| Strings per MPPT | 2 |
| Surge protection level AC | II |
| Surge protection level DC | II |
| THD (%) | 3 |
| Topology | Transformerless |
| Warranty (years) | 5/10 |
| Weight (kg) | 31 |
INFINITY
TypeInverterGridStoragePhaseSingle phase
Capacity0.3 kW
Price—
Details
MAC TL3 X LV
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
MAC TL3 X MV
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
MAX
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
MAX TL3 LV
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details
MAX TL3 X HV
TypeInverterGridOn-gridPhaseThree phase
Capacity
Price—
Details