Home Products Felicity Inverter Hybrid
15 kW three-phase hybrid, sized to a 15 kW three-phase connection.
AC output voltage (V) 220/230 Battery type Lead-acid, Lithium-ion IP rating IP65 Max charge current (A) 280 Max efficiency (%) 97.6 Max PV input power (kW) 24 Max PV voltage (V) 800 MPPT count 2
All specifications 66 AC AC output voltage (V) 220/230 Grid type Hybrid Phase Three phase AC grid connection type 3L+N+PE AC input voltage (V) 220-230 AC output line voltage (V) 380-400 Grid frequency (Hz) 50/60 Grid frequency range 50 (Hz) 45-55 Grid frequency range 60 (Hz) 55-65 Grid regulation NRS 097-2-1, VDE4105, EN50549-1, AS 4777.2, GB/T 34120, GB/T 34133, GB/T 34129 Max AC input current (A) 23.9 Max AC passthrough (A) 70 Max apparent power (kVA) 16.5 Max output current (A) 23.9 Nominal AC input line voltage (V) 380-400 Output frequency (Hz) 50/60 Power factor adjustable range 0.8 leading to 0.8 lagging Rated AC output current (A) 21.8
PV and DC DC switch Yes Max PV input current (A) 36+36 Max PV input power (kW) 24 Max PV voltage (V) 800 Monitor module WiFi/4G MPPT count 2 MPPT full load voltage range (V) 416-800 MPPT voltage range (V) 160-650 Rated PV input voltage (V) 550 Strings per MPPT 2+2 Surge protection level DC II
Battery Battery class Low voltage Battery type Lead-acid, Lithium-ion Battery voltage range (V) 40-60 BMS communication RS485, CAN Charge algorithm Self-adaption to BMS Max charge current (A) 280 Max discharge current (A) 280 Number of battery inputs 2 Approved battery families Felicity
Protection AC short circuit protection Yes Ground fault monitoring Yes IP rating IP65 Max output overcurrent protection (A) 92 Max short circuit current (A) 54+54 Overload protection Yes Protection DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection, DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (AFCI), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, Overvoltage Load Drop Protection, Residual Current (RCD) Detection Surge duration (s) 10 Surge power multiple 2 Surge protection level AC II
Communication Communication interface RS485, RS232 Display LCD
General Rated power (kVA) 15 Rated power (kW) 15 Cooling Air Cooling Dimension (mm) 450 x 268 x 750 Input voltage range (V) 184-264.5 Max efficiency (%) 97.6 Operating temperature (°C) -25 to 60 (>45 derating) Package dimension (mm) 889 x 397 x 566 Package weight (kg) 60.2 Parallel units 10 Safety standard IEC/EN 62109-1, IEC/EN 62109-2 Startup voltage (V) 160 Topology Non-Isolated Transfer time (ms) 20 Warranty (years) 5/10 (depends on installation site) Weight (kg) 48.7