AI100 48V
TypeInverterGridStoragePhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVBM 48V
10 kW off-grid with a 200 A charge limit, the same duty with more headroom for several heavy starts at once.
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 8 |
| Rated power (kW) | 8 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 40 |
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
| Battery voltage range (V) | 42-60 |
| BMS communication | RS485, CAN |
| Bulk charging voltage (V) | 56.4 |
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Communication interface | RS485, RS232, CAN |
| Cooling | Air Cooling |
| Dimension (mm) | 525 x 189.2 x 490 |
| Display | LCD, LED |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| High DC input recovery (V) | 56.4 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Input voltage range (V) | 90-280 |
| Input voltage waveform | Sinusoidal (utility or generator) |
| IP rating | IP65 |
| Line mode efficiency (%) | 95 |
| Line mode output waveform | Same As Input Waveform |
| Low battery recovery load over 50pct (V) | 46 |
| Low battery recovery load under 50pct (V) | 47 |
| Low DC input shutdown load over 50pct (V) | 42 |
| Low DC input shutdown load under 50pct (V) | 43 |
| Low line disconnect apl (V) | 90 |
| Low line disconnect UPS (V) | 170 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Low line reconnect UPS (V) | 180 |
| Max AC charge current (A) | 150 |
| Max AC input voltage (V) | 280 |
| Max AC passthrough (A) | 53 |
| Max charge current (A) | 150 |
| Max charging voltage (V) | 60 |
| Max efficiency (%) | 94.5 |
| Max generator input current (A) | 32 |
| Max inverter rectifier current (A) | 40 |
| Max output current (A) | 40 |
| Max PV input current (A) | 20+20 |
| Max PV input power (kW) | 10 |
| Max PV voltage (V) | 450 |
| Max smart load output current (A) | 40 |
| Max solar charge current (A) | 150 |
| Monitor module | Built-In WiFi |
| Motor start capable | Yes |
| MPPT count | 1 |
| MPPT voltage range (V) | 100-450 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | 0-50 |
| Output frequency (Hz) | 50/60 |
| Output voltage regulation (%) | 5 |
| Overload protection | Yes |
| Overload trip time over 105pct load (s) | 10 |
| Overload trip time over 150pct load (s) | 5 |
| Package dimension (mm) | 597 x 267 x 572 |
| Package weight (kg) | 28.3 |
| Parallel units | 6 |
| Pass through without battery | Yes |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| PV voltage working range (V) | 90-450 |
| Short circuit protection battery mode | Electronic Circuit |
| Short circuit protection line mode | Circuit Breaker |
| Startup voltage (V) | 160 |
| Storage temperature (°C) | -15 to 60 |
| Strings per MPPT | 2 |
| Surge duration (s) | 5 |
| Surge power multiple | 2 |
| Topology | Low-Frequency |
| Transfer time apl (ms) | 20 |
| Transfer time UPS (ms) | 10 |
| Waveform | Pure sine wave |
| Weight (kg) | 24.3 |
| AC output voltage (V) | 230 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 10 |
| Rated power (kW) | 10 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 230 |
| AC short circuit protection | Yes |
| Backup max output current (A) | 46 |
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
| Battery voltage range (V) | 42-60 |
| BMS communication | RS485, CAN |
| Bulk charging voltage (V) | 56.4 |
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Communication interface | RS485, RS232, CAN |
| Cooling | Air Cooling |
| Dimension (mm) | 525 x 189.2 x 490 |
| Display | LCD, LED |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 50/60 |
| High DC input recovery (V) | 56.4 |
| High line disconnect (V) | 280 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 270 |
| Input voltage range apl (V) | 90-280 |
| Input voltage range UPS (V) | 170-280 |
| Input voltage range (V) | 90-280 |
| Input voltage waveform | Sinusoidal (utility or generator) |
| IP rating | IP65 |
| Line mode efficiency (%) | 95 |
| Line mode output waveform | Same As Input Waveform |
| Low battery recovery load over 50pct (V) | 46 |
| Low battery recovery load under 50pct (V) | 47 |
| Low DC input shutdown load over 50pct (V) | 42 |
| Low DC input shutdown load under 50pct (V) | 43 |
| Low line disconnect apl (V) | 90 |
| Low line disconnect UPS (V) | 170 |
| Low line frequency disconnect (Hz) | 40 |
| Low line frequency reconnect (Hz) | 42 |
| Low line reconnect apl (V) | 100 |
| Low line reconnect UPS (V) | 180 |
| Max AC charge current (A) | 200 |
| Max AC input voltage (V) | 280 |
| Max AC passthrough (A) | 65 |
| Max charge current (A) | 200 |
| Max charging voltage (V) | 60 |
| Max efficiency (%) | 94.5 |
| Max generator input current (A) | 32 |
| Max inverter rectifier current (A) | 46 |
| Max output current (A) | 46 |
| Max PV input current (A) | 20+20 |
| Max PV input power (kW) | 11 |
| Max PV voltage (V) | 450 |
| Max smart load output current (A) | 46 |
| Max solar charge current (A) | 200 |
| Monitor module | Built-In WiFi |
| Motor start capable | Yes |
| MPPT count | 1 |
| MPPT voltage range (V) | 100-450 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | 0-50 |
| Output frequency (Hz) | 50/60 |
| Output voltage regulation (%) | 5 |
| Overload protection | Yes |
| Overload trip time over 105pct load (s) | 10 |
| Overload trip time over 150pct load (s) | 5 |
| Package dimension (mm) | 597 x 267 x 572 |
| Package weight (kg) | 28.3 |
| Parallel units | 6 |
| Pass through without battery | Yes |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| PV voltage working range (V) | 90-450 |
| Short circuit protection battery mode | Electronic Circuit |
| Short circuit protection line mode | Circuit Breaker |
| Startup voltage (V) | 160 |
| Storage temperature (°C) | -15 to 60 |
| Strings per MPPT | 2 |
| Surge duration (s) | 5 |
| Surge power multiple | 2 |
| Topology | Low-Frequency |
| Transfer time apl (ms) | 20 |
| Transfer time UPS (ms) | 10 |
| Waveform | Pure sine wave |
| Weight (kg) | 24.3 |
AI100 48V
TypeInverterGridStoragePhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVAM 48V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVCM 12V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity2 kW
Price—
Details
IVCM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity3.2 kW
Price—
Details
IVDM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity4.2 kW
Price—
Details
IVEM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity3 kW
Price$288
Details