- Home
- Products
- Felicity
- Inverter
- Off-grid
2 kW off-grid at 6.5 kg, for lights, phones, a television and a small fridge on a 12 V bank.
| AC output voltage (V) | 230 |
|---|
| IP rating | IP21 |
|---|
| Max charge current (A) | 120 |
|---|
| Max efficiency (%) | 90 |
|---|
| Max PV input power (kW) | 0.8 |
|---|
| Max PV voltage (V) | 105 |
|---|
| MPPT count | 1 |
|---|
| MPPT voltage range (V) | 30-90 |
|---|
All specifications79
AC
| AC output voltage (V) | 230 |
|---|
| Grid type | Off-grid |
|---|
| Phase | Single phase |
|---|
| AC grid connection type | L+N+PE |
|---|
| AC input voltage (V) | 230 |
|---|
| Grid frequency (Hz) | 50/60 |
|---|
| High line frequency reconnect (Hz) | 63 |
|---|
| Line mode output waveform | Same As Input Waveform |
|---|
| Low line frequency reconnect (Hz) | 42 |
|---|
| Max AC input voltage (V) | 280 |
|---|
| Max AC passthrough (A) | 25 |
|---|
| Output frequency (Hz) | 50/60 |
|---|
PV and DC
| High DC input recovery (V) | 14.5 |
|---|
| High line disconnect (V) | 280 |
|---|
| High line frequency disconnect (Hz) | 65 |
|---|
| Low DC input shutdown load over 50pct (V) | 9.6 |
|---|
| Low DC input shutdown load under 50pct (V) | 10.2 |
|---|
| Low line disconnect apl (V) | 90 |
|---|
| Low line disconnect UPS (V) | 170 |
|---|
| Low line frequency disconnect (Hz) | 40 |
|---|
| Max PV input power (kW) | 0.8 |
|---|
| Max PV voltage (V) | 105 |
|---|
| Monitor module | Built-In WiFi |
|---|
| MPPT count | 1 |
|---|
| MPPT efficiency (%) | 99 |
|---|
| MPPT voltage range (V) | 30-90 |
|---|
| Strings per MPPT | 1 |
|---|
Battery
| Battery class | Low voltage |
|---|
| Nominal battery voltage (V) | 12 |
|---|
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
|---|
| Battery voltage range (V) | 10.5-15.75 |
|---|
| BMS communication | RS485, CAN |
|---|
| Bulk charging voltage (V) | 14.1 |
|---|
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
|---|
| Floating charge voltage (V) | 13.5 |
|---|
| Low battery recovery load over 50pct (V) | 10.6 |
|---|
| Low battery recovery load under 50pct (V) | 11.2 |
|---|
| Max AC charge current (A) | 120 |
|---|
| Max charge current (A) | 120 |
|---|
| Max charging voltage (V) | 15 |
|---|
| Max discharge current (A) | 165 |
|---|
| Max solar charge current (A) | 60 |
|---|
| Number of battery inputs | 1 |
|---|
| Pass through without battery | Yes |
|---|
| Short circuit protection battery mode | Electronic Circuit |
|---|
| Approved battery families | Felicity |
|---|
Protection
| AC short circuit protection | Yes |
|---|
| IP rating | IP21 |
|---|
| Overload protection | Yes |
|---|
| Overload trip time over 105pct load (s) | 10 |
|---|
| Overload trip time over 150pct load (s) | 5 |
|---|
| Protection | Over Charge Protection, Overload Protection, Output Short Circuit Protection, Over Temperature Protection |
|---|
Communication
| Communication interface | RS485, CAN |
|---|
| Display | LCD, LED |
|---|
General
| Rated power (kVA) | 2 |
|---|
| Rated power (kW) | 2 |
|---|
| Cooling | Air Cooling |
|---|
| Dimension (mm) | 276 x 128 x 356 |
|---|
| High line reconnect (V) | 270 |
|---|
| Input voltage range apl (V) | 90-280 |
|---|
| Input voltage range UPS (V) | 170-280 |
|---|
| Input voltage range (V) | 90-280 |
|---|
| Input voltage waveform | Sinusoidal (utility or generator) |
|---|
| Low line reconnect apl (V) | 100 |
|---|
| Low line reconnect UPS (V) | 180 |
|---|
| Max efficiency (%) | 90 |
|---|
| Max inverter rectifier current (A) | 15 |
|---|
| Motor start capable | Yes |
|---|
| Operating temperature (°C) | -10 to 55 |
|---|
| Package dimension (mm) | 438 x 202 x 358 |
|---|
| Package weight (kg) | 8.2 |
|---|
| Parallel units | 6 |
|---|
| Startup voltage (V) | 10.5 |
|---|
| Storage temperature (°C) | -15 to 60 |
|---|
| Topology | High-Frequency |
|---|
| Transfer time apl (ms) | 20 |
|---|
| Transfer time UPS (ms) | 4 |
|---|
| Waveform | Pure sine wave |
|---|
| Weight (kg) | 6.5 |
|---|