EN
  1. Home
  2. Products
  3. Felicity
  4. Inverter
  5. Off-grid
Felicity IVEM 48V SALV Off-grid inverter 3 kWFelicity IVEM 48V SALV Off-grid inverter 3 kW - 2Felicity IVEM 48V SALV Off-grid inverter 3 kW - 3Felicity IVEM 48V SALV Off-grid inverter 3 kW - 4Felicity IVEM 48V SALV Off-grid inverter 3 kW - 5

Felicity IVEM 48V SALV Off-grid inverter 3 kW

TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltageSystem48 V Capacity3 kW5 kW
Price—

Coming in 4 weeks

Description

3 kW off-grid built for a 127 V mains supply, IP21-rated with a 60 A charge limit, for markets on that voltage.

Key specifications

AC output voltage (V)127
IP ratingIP21
Max charge current (A)60
Max efficiency (%)93
Max PV input power (kW)4
Max PV voltage (V)500
MPPT count1
MPPT voltage range (V)120-450
All specifications86

AC

AC output voltage (V)127
Grid typeOff-grid
PhaseSingle phase
AC grid connection typeL+N+PE
AC input voltage (V)127
Grid frequency (Hz)60
High line frequency reconnect (Hz)63
Line mode output waveformSame As Input Waveform
Low line frequency reconnect (Hz)49
Max AC input voltage (V)140
Max AC passthrough (A)40
Max output current (A)30
Output frequency (Hz)60
Output voltage regulation (%)5

PV and DC

High DC input recovery (V)56.4
High line disconnect (V)140
High line frequency disconnect (Hz)65
Low DC input shutdown load over 50pct (V)42
Low DC input shutdown load under 50pct (V)43
Low line disconnect apl (V)65
Low line disconnect UPS (V)90
Low line frequency disconnect (Hz)47
Max PV input current (A)15
Max PV input power (kW)4
Max PV voltage (V)500
Monitor moduleBuilt-In WiFi
MPPT count1
MPPT voltage range (V)120-450
PV voltage working range (V)120-450
Strings per MPPT1

Battery

Battery classLow voltage
Nominal battery voltage (V)48
Battery typeAGM, Flooded, Lithium-ion, Self-Defined
Battery voltage range (V)42-63
BMS communicationRS485
Bulk charging voltage (V)56.4
Charge algorithmThree-Stage: Boost CC, Boost CV, Float
Floating charge voltage (V)54
Low battery recovery load over 50pct (V)46
Low battery recovery load under 50pct (V)47
Max AC charge current (A)60
Max charge current (A)60
Max charging voltage (V)60
Max solar charge current (A)60
Number of battery inputs1
Pass through without batteryYes
Short circuit protection battery modeElectronic Circuit
Approved battery familiesFelicity

Protection

AC short circuit protectionYes
IP ratingIP21
Overload protectionYes
Overload trip time over 105pct load (s)10.5
Overload trip time over 150pct load (s)5.5
ProtectionOverload Protection, Over Temperature Protection, Short Circuit Protection
Short circuit protection line modeCircuit Breaker
Surge duration (s)5
Surge power multiple2

Communication

DisplayLCD

General

Rated power (kVA)3
Rated power (kW)3
CoolingAir Cooling
Dimension (mm)328 x 130 x 440
High line reconnect (V)135
Input voltage range apl (V)65-140
Input voltage range UPS (V)90-140
Input voltage range (V)65-140
Input voltage waveformSinusoidal (utility or generator)
Line mode efficiency (%)95
Low line reconnect apl (V)70
Low line reconnect UPS (V)95
Max efficiency (%)93
Max inverter rectifier current (A)30
Motor start capableYes
Operating temperature (°C)-10 to 50
Package dimension (mm)542 x 224 x 430
Package weight (kg)14.2
Parallel units0
Safety standardIEC 62109-1, IEC 62109-2
Startup voltage (V)100
Storage temperature (°C)-15 to 60
TopologyHigh-Frequency
Transfer time apl (ms)20
Transfer time (ms)50
Transfer time UPS (ms)10
WaveformPure sine wave
Weight (kg)11.9

Download center

Reviews

No reviews yet.

Log in to write a review

See also

Felicity IVEM 24V II inverter off-grid low voltage single phaseIVEM 24V IITypeInverterGridOff-gridPhaseSingle phaseCapacity4 kWBatteryLow voltagePrice$215Details
Felicity IVEM 48V inverter off-grid low voltage single phaseIVEM 48VTypeInverterGridOff-gridPhaseSingle phaseCapacity5 kW6 kW8 kWBatteryLow voltagePrice$710Details
Felicity IVEM 48V II inverter off-grid low voltage single phaseIVEM 48V IITypeInverterGridOff-gridPhaseSingle phaseCapacity6 kW8 kW12 kWBatteryLow voltagePrice$380Details