AI100 48V
TypeInverterGridStoragePhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVEM 48V SALV
3 kW off-grid built for a 127 V mains supply, IP21-rated with a 60 A charge limit, for markets on that voltage.
| AC output voltage (V) | 127 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 3 |
| Rated power (kW) | 3 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 127 |
| AC output voltage (V) | 127 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 127 |
| AC output voltage (V) | 127 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 3 |
| Rated power (kW) | 3 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 127 |
| AC short circuit protection | Yes |
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
| Battery voltage range (V) | 42-63 |
| BMS communication | RS485 |
| Bulk charging voltage (V) | 56.4 |
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Cooling | Air Cooling |
| Dimension (mm) | 440 x 130 x 328 |
| Display | LCD |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 60 |
| High DC input recovery (V) | 56.4 |
| High line disconnect (V) | 140 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 135 |
| Input voltage range apl (V) | 65-140 |
| Input voltage range UPS (V) | 90-140 |
| Input voltage range (V) | 65-140 |
| Input voltage waveform | Sinusoidal (utility or generator) |
| IP rating | IP21 |
| Line mode efficiency (%) | 95 |
| Line mode output waveform | Same As Input Waveform |
| Low battery recovery load over 50pct (V) | 46 |
| Low battery recovery load under 50pct (V) | 47 |
| Low DC input shutdown load over 50pct (V) | 42 |
| Low DC input shutdown load under 50pct (V) | 43 |
| Low line disconnect apl (V) | 65 |
| Low line disconnect UPS (V) | 90 |
| Low line frequency disconnect (Hz) | 47 |
| Low line frequency reconnect (Hz) | 49 |
| Low line reconnect apl (V) | 70 |
| Low line reconnect UPS (V) | 95 |
| Max AC charge current (A) | 60 |
| Max AC input voltage (V) | 140 |
| Max AC passthrough (A) | 40 |
| Max charge current (A) | 60 |
| Max charging voltage (V) | 60 |
| Max efficiency (%) | 93 |
| Max inverter rectifier current (A) | 30 |
| Max output current (A) | 30 |
| Max PV input current (A) | 15 |
| Max PV input power (kW) | 4 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 60 |
| Monitor module | Built-In WiFi |
| Motor start capable | Yes |
| MPPT count | 1 |
| MPPT voltage range (V) | 120-450 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -10 to 50 |
| Output frequency (Hz) | 60 |
| Output voltage regulation (%) | 5 |
| Overload protection | Yes |
| Overload trip time over 105pct load (s) | 10.5 |
| Overload trip time over 150pct load (s) | 5.5 |
| Package dimension (mm) | 542 x 224 x 430 |
| Package weight (kg) | 14.2 |
| Parallel units | 0 |
| Pass through without battery | Yes |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| PV voltage working range (V) | 120-450 |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Short circuit protection battery mode | Electronic Circuit |
| Short circuit protection line mode | Circuit Breaker |
| Startup voltage (V) | 100 |
| Storage temperature (°C) | -15 to 60 |
| Strings per MPPT | 1 |
| Surge duration (s) | 5 |
| Surge power multiple | 2 |
| Topology | High-Frequency |
| Transfer time apl (ms) | 20 |
| Transfer time (ms) | 50 |
| Transfer time UPS (ms) | 10 |
| Waveform | Pure sine wave |
| Weight (kg) | 11.9 |
| AC output voltage (V) | 127 |
|---|---|
| Battery class | Low voltage |
| Grid type | Off-grid |
| Nominal battery voltage (V) | 48 |
| Phase | Single phase |
| Rated power (kVA) | 5 |
| Rated power (kW) | 5 |
| AC grid connection type | L+N+PE |
| AC input voltage (V) | 127 |
| AC short circuit protection | Yes |
| Battery type | AGM, Flooded, Lithium-ion, Self-Defined |
| Battery voltage range (V) | 42-63 |
| BMS communication | RS485 |
| Bulk charging voltage (V) | 56.4 |
| Charge algorithm | Three-Stage: Boost CC, Boost CV, Float |
| Cooling | Air Cooling |
| Dimension (mm) | 487.4 x 137 x 343 |
| Display | LCD |
| Floating charge voltage (V) | 54 |
| Grid frequency (Hz) | 60 |
| High DC input recovery (V) | 56.4 |
| High line disconnect (V) | 140 |
| High line frequency disconnect (Hz) | 65 |
| High line frequency reconnect (Hz) | 63 |
| High line reconnect (V) | 135 |
| Input voltage range apl (V) | 65-140 |
| Input voltage range UPS (V) | 90-140 |
| Input voltage range (V) | 65-140 |
| Input voltage waveform | Sinusoidal (utility or generator) |
| IP rating | IP21 |
| Line mode efficiency (%) | 95 |
| Line mode output waveform | Same As Input Waveform |
| Low battery recovery load over 50pct (V) | 46 |
| Low battery recovery load under 50pct (V) | 47 |
| Low DC input shutdown load over 50pct (V) | 42 |
| Low DC input shutdown load under 50pct (V) | 43 |
| Low line disconnect apl (V) | 65 |
| Low line disconnect UPS (V) | 90 |
| Low line frequency disconnect (Hz) | 47 |
| Low line frequency reconnect (Hz) | 49 |
| Low line reconnect apl (V) | 70 |
| Low line reconnect UPS (V) | 95 |
| Max AC charge current (A) | 100 |
| Max AC input voltage (V) | 140 |
| Max AC passthrough (A) | 63 |
| Max charge current (A) | 100 |
| Max charging voltage (V) | 60 |
| Max efficiency (%) | 93 |
| Max inverter rectifier current (A) | 50 |
| Max output current (A) | 50 |
| Max PV input current (A) | 20 |
| Max PV input power (kW) | 6 |
| Max PV voltage (V) | 500 |
| Max solar charge current (A) | 100 |
| Monitor module | Built-In WiFi |
| Motor start capable | Yes |
| MPPT count | 1 |
| MPPT voltage range (V) | 120-450 |
| Number of battery inputs | 1 |
| Operating temperature (°C) | -10 to 50 |
| Output frequency (Hz) | 60 |
| Output voltage regulation (%) | 5 |
| Overload protection | Yes |
| Overload trip time over 105pct load (s) | 10.5 |
| Overload trip time over 150pct load (s) | 5.5 |
| Package dimension (mm) | 589 x 231 x 443 |
| Package weight (kg) | 17.3 |
| Parallel units | 6 |
| Pass through without battery | Yes |
| Protection | Overload Protection, Over Temperature Protection, Short Circuit Protection |
| PV voltage working range (V) | 120-450 |
| Safety standard | IEC 62109-1, IEC 62109-2 |
| Short circuit protection battery mode | Electronic Circuit |
| Short circuit protection line mode | Circuit Breaker |
| Startup voltage (V) | 100 |
| Storage temperature (°C) | -15 to 60 |
| Strings per MPPT | 1 |
| Surge duration (s) | 5 |
| Surge power multiple | 2 |
| Topology | High-Frequency |
| Transfer time apl (ms) | 20 |
| Transfer time (ms) | 50 |
| Transfer time UPS (ms) | 10 |
| Waveform | Pure sine wave |
| Weight (kg) | 14.9 |
AI100 48V
TypeInverterGridStoragePhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVAM 48V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price—
Details
IVBM 48V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity
Price$810
Details
IVCM 12V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity2 kW
Price—
Details
IVCM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity3.2 kW
Price—
Details
IVDM 24V
TypeInverterGridOff-gridPhaseSingle phaseBatteryLow voltage
Capacity4.2 kW
Price—
Details